For the purpose of protecting the Operator from hazards resulting from the manual handling of the
loads, refer to the technical specifications section which lists the weight of each individual part.
The person assigned to remove the device from its packaging must be trained in the risks
involved in this operation.
To lift the load correctly without risking injury to the spine:
The back must be kept straight
The torso must be kept upright
The weight being lifted must be held as tightly as possible against the body
To move loads heavier than 25 kg (if the operator is female the limit weight is 15 kg, the
value set by the applicable legislation at the time this manual was revised) ask other
persons for help or use an appropriate lifting device.
Do not raise the parts and carry them above shoulder level.
Place the box in an area where it is easy to unpack and assemble the parts.
When opening the packaging, do not use sharp or pointed instruments which might damage the
parts inside.
It is advisable to keep the packaging for reuse should the device need to be shipped another time
(e.g.: technical support); the original packaging ensures safe transport.
All components on the device are easy to handle
.
19
6.
Assembly
6.1
Assembly of the model
Make sure the device has no visible signs of damage or dents caused during transport. If in
doubt, contact your retailer or the Manufacturer.
The main images show the N700 and N800 models, but also apply to the N300 and N500
models.
Remove all parts from the packaging.
Place the packaging contents on a flat surface and make sure that all the components
are in a good condition and are all present.
Position the support column vertically (1) with respect to the base (2), aligning it with
the stop, and fasten it using the bolts supplied (3).
Use an M19 hex key to tighten the bolts securely (3).
WARNING!!! THE NUTS AND BOLTS MUST BE TIGHTENED TO THE SPECIFIED TORQUE
INDICATED BELOW. USE AN APPROPRIATE TORQUE SPANNER AS INDICATED
BELOW.
ASSEMBLING THE LIFT BOOM ON VERSIONS N300 ‐ N500
‐ Assemble the plastic flange (16) joining the two halves and place it between the lift boom (4)
and the column (1) (Fig. A Version N300 ‐ N500).
ASSEMBLING THE LIFT BOOM ON VERSIONS N700 ‐ N800
‐ Insert the boom (4) in the relative flange (5) located at the upper end of the support column
and fasten it with the pin (6) and the safety lock (7). (Fig. B Version N700 ‐ N800).