5 Installation at Site
31 of 116
CHTRa
WARNING
Hot surfaces due to heating of components for assembly/dismantling
Risk of burns!
▷
Wear heat-resistant protective gloves.
▷
Remove flammable substances from the danger zone.
4. To facilitate fitting, the coupling hubs may be heated uniformly to a
temperature of 80 °C max. Elastomeric parts must be removed before heating.
Elastomeric parts which have been heated must not be used any more.
Fig. 13:
Fit coupling hub (example)
Pump size
Thread size X
2
M12
3
M12
4
M16
5
M16 or M20
5. Fit the coupling hubs until the shaft end and the hub face are in alignment.
Fig. 14:
Coupling hub with grub screw
A
Grub screw
6. Securely tighten the grub screws.
7. Fit the retaining ring, if applicable, to the coupling hub.
5.8 Preparing the adjusting screws
Prepare the adjusting screws and position them on either side of the foundation
bolts as shown in the sketch.