6 Commissioning/Start-up/Shutdown
26 of 52
Calio S
1157.8117/01-EN
6.1.3 Start-up
DANGER
Non-compliance with the permissible pressure and temperature limits if the pump
is operated with the suction and discharge lines closed.
Hot fluids escaping!
▷
Never operate the pump with the shut-off elements in the suction line and/or
discharge line closed.
▷
Only start up the pump set against a slightly or completely open discharge-side
shut-off element.
DANGER
Excessive temperatures due to insufficient lubrication of the plain bearings
Damage to the pump set!
▷
Never operate the pump set without liquid fill.
▷
Prime the pump as per operating instructions.
▷
Always operate the pump within the permissible operating range.
WARNING
Hot surfaces (pump and piping take on the temperature of the fluid handled).
Risk of burns!
▷
Do not touch hot surfaces.
▷
Use appropriate personal protective equipment.
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
▷
Switch off the pump (set) immediately.
▷
Eliminate the causes before returning the pump set to service.
ü
The system piping has been cleaned.
ü
Pump set, suction line and inlet tank, if fitted, have been vented and primed with
the fluid to be pumped.
ü
The priming lines and venting lines have been closed.
1. Fully open the shut-off element in the suction line.
2. Close or slightly open the shut-off element in the discharge line.
3. Start up the pump set.
Содержание Calio S
Страница 1: ...High efficiency Circulator Pump Calio S Installation Operating Manual...
Страница 35: ...7 Operation 35 of 52 Calio S 1157 8117 01 EN H Hmax HS Hmin Q Fig 12 Proportional pressure Control settings...
Страница 50: ......
Страница 51: ......
Страница 52: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 1157 8117 01 EN...