4 Description of the Pump (Set)
14 of 72
Amarex N
4 Description of the Pump (Set)
4.1 General description
Pump for handling untreated waste water containing long fibres and solid
substances, fluids containing air/gas as well as raw, activated and digested sludge.
4.2 Designation
Example: Amarex N F 50 - 170 / 012 YLG 120
Table 6:
Designation key
Code
Description
Amarex N
Type series
F
Impeller type, e.g. F = free flow impeller
50
Nominal discharge nozzle diameter [mm]
170
Code number for hydraulic system size
01
Code number for motor size
2
Number of poles
YL
Motor version, e.g. YL = with explosion protection T4 (40
°C)
G
Casing material, e.g. G = grey cast iron
120
Nominal impeller diameter [mm]
4.3 Name plate
TYPE
No.
Q
P
2
KSB SAS
F-59320 Sequedin
Mat. No: 39023373
TEMP. MAX.
WARNUNG - NICHT UNTER SPANNUNG ÖFFNEN
WARNING - DO NOT OPEN WHEN ENERGIZED
AVERTISSEMENT - NE PAS OUVRIR SOUS TENSION
a)
b)
°C
kg
H
Motor
IP 68 SUBM. MAX. 25 m CLASS F
3~
kW
V
Hz cos
φ
min
-1
A
I
A
/I
N
S1
Amarex N S50 - 172 / 012 ULG-160
39100021
0.30 5.90 l/s
32 2 m
55
47
S1101
2011
2011
DKN 82.2-2U
1,9
2835
4,5
4,4
0,83
400
50
TYPE
No.
Q
P
2
KSB SAS
F-59320 Sequedin
Mat. No: 39023372
TEMP. MAX.
WARNUNG - NICHT UNTER SPANNUNG ÖFFNEN
WARNING - DO NOT OPEN WHEN ENERGIZED
AVERTISSEMENT - NE PAS OUVRIR SOUS TENSION
°C
kg
H
Motor
IP 68 SUBM. MAX. 25 m CLASS F
3~
M.-No.
kW
V
Hz cos
φ
min
-1
A
I
A
/I
N
S1
Amarex N S50 - 172 / 012 YLG-160
39100022
0.30 5.90 l/s
32 2 m
55
47
S1101
DKN 82.2-2U
1,9
2835
4,5
4,4
0,83
400
50
123456
II2G Ex dc IIB T4
0081
II2G Ex d IIB T4 Gb LCIE 03 ATEX 6428 X
2011
1
2
3
4
6
5
7
8
9
10
11
12
13
15
16
14
17
18
19
20
21
22
23
Fig. 1:
Name plate (example) a) Standard pump set b) Explosion-proof pump set
1
Designation
2
KSB order number
3
Flow rate
4
Maximum fluid and ambient temperature
5
Enclosure
6
Motor type
7
Rated power
8
Rated speed
9
Rated voltage
10
Rated current
11
Head
12
Series code
13
Total weight
14
Year of construction
15
Maximum submergence
16
Thermal class of winding insulation
17
Power factor at design point
18
Mode of operation
19
Rated frequency
20
Starting current ratio
21
ATEX marking for the submersible motor
22
ATEX marking for the pump set
23
Motor number
Key to the series code
S = series, 11 = year of construction 2011, 01 = week 1
Содержание Amarex N