2 Safety
10 of 72
Amarex N
2.5 Consequences and risks caused by non-compliance with this manual
▪
Non-compliance with this operating manual will lead to forfeiture of warranty
cover and of any and all rights to claims for damages.
▪
Non-compliance can, for example, have the following consequences:
–
Hazards to persons due to electrical, thermal, mechanical and chemical
effects and explosions
–
Failure of important product functions
–
Failure of prescribed maintenance and servicing practices
–
Hazard to the environment due to leakage of hazardous substances
2.6 Safety awareness
In addition to the safety information contained in this manual and the intended use,
the following safety regulations shall be complied with:
▪
Accident prevention, health and safety regulations
▪
Explosion protection regulations
▪
Safety regulations for handling hazardous substances
▪
Applicable standards and laws
2.7 Safety information for the operator/user
▪
The operator shall fit contact guards for hot, cold and moving parts and check
that the guards function properly.
▪
Do not remove any contact guards during operation.
▪
Provide the personnel with protective equipment and make sure it is used.
▪
Contain leakages (e.g. at the shaft seal) of hazardous fluids handled (e.g.
explosive, toxic, hot) so as to avoid any danger to persons and the environment.
Adhere to all relevant laws.
▪
Eliminate all electrical hazards. (In this respect refer to the applicable national
safety regulations and/or regulations issued by the local energy supply
companies.)
▪
If shutting down the pump does not increase potential risk, fit an emergency-
stop control device in the immediate vicinity of the pump (set) during pump set
installation.
2.8 Safety information for maintenance, inspection and installation work
▪
Modifications or alterations of the pump are only permitted with the
manufacturer's prior consent.
▪
Use only original spare parts or parts authorised by the manufacturer. The use of
other parts can invalidate any liability of the manufacturer for resulting damage.
▪
The operator ensures that all maintenance, inspection and installation work is
performed by authorised, qualified specialist personnel who are thoroughly
familiar with the manual.
▪
Only carry out work on the pump (set) during standstill of the pump.
▪
The pump casing must have cooled down to ambient temperature.
▪
Pump pressure must have been released and the pump must have been drained.
▪
When taking the pump set out of service always adhere to the procedure
described in the manual.
▪
Decontaminate pumps which handle fluids posing a health hazard.
▪
As soon as the work has been completed, re-install and/or re-activate any safety-
relevant and protective devices. Before returning the product to service, observe
all instructions on commissioning.