7 Servicing/Maintenance
54 of 84
Amarex N
2563.84/08-EN
7.4.4.2 Removing the mechanical seal and motor part (version UL)
ü
The oil has been drained. (
1. Undo and remove screws 914.02 at bearing bracket 330.
2. Remove rotor unit 818 from bearing bracket 330.
3. Press mating ring 433.02 out of bearing bracket 330.
4. Remove circlip 932.02.
5. Take bearing bracket 330 off rotor 818.
6. Remove circlip 932.03.
7. Remove primary ring 433.01.
8. Pull off mating ring carrier 476.
9. Take mating ring 433.01 out of mating ring carrier 476.
10. Remove circlip 932.01.
11. Pull off rolling element bearing 321.02.
12. Pull off rolling element bearing 321.01.
7.5 Reassembling the pump set
7.5.1 General information/Safety regulations
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
CAUTION
Improper reassembly
Damage to the pump!
▷
Reassemble the pump (set) in accordance with the general rules of sound
engineering practice.
▷
Use original spare parts only.
NOTE
Before reassembling the motor section, check that all joints relevant to explosion
protection (flamepaths) are undamaged. Any components with damaged
flamepaths must be replaced. Refer to the "Flamepaths" annex for the position of
the flamepaths.
Sequence
Always reassemble the pump set in accordance with the corresponding general
assembly drawing.
Sealing elements
▪
O-rings
– Check O-rings for any damage and replace by new O-rings, if required.
▪
Assembly adhesives
– Avoid the use of assembly adhesives, if possible.
Tightening torques
For reassembly, tighten all screws and bolts as specified in this manual.
(
Содержание Amarex N series
Страница 80: ...Index 80 of 84 Amarex N 2563 84 08 EN W Warnings 7 Warranty claims 6...