7 Servicing/Maintenance
47 of 84
Amarex N
2563.84/08-EN
Draining the lubricant
1. Position the pump set as shown.
2563:107
2563:106
903
411
a)
b)
Fig. 18:
Draining the lubricant a) Versions YL & WL for sizes 50-170, 50-172 and
65-220; b) Versions YL & WL
2. Place a suitable container under the screw plug.
WARNING
Excess pressure in the lubricant reservoir
Liquid spurting out when the lubricant reservoir is opened at operating
temperature!
▷
Open the screw plug of the lubricant reservoir very carefully.
3. Undo screw plug 903 with joint ring 411 and drain off the lubricant.
NOTE
Paraffin oil is bright and transparent in appearance. A slight discolouration, caused
by the running-in process of new mechanical seals or small amounts of leakage
from the fluid handled, has no detrimental effect. However, if the coolant is
severely contaminated by the fluid handled, this suggests a defect at the
mechanical seals.
Filling in the lubricant
1. Position the pump set as shown.
a)
b)
M = 40 mm
2563:109
2563:108
M = 40 mm
903
411
Fig. 19:
Filling in the lubricant level a) Versions YL & WL; b) Versions YL & WL for size
50-170, 50-172 and 65-220
2. Fill lubricant through the lubricant filler opening until the lubricant in the
lubricant reservoir reaches the required level M (see the following table).
3. Screw in screw plug 903 with new joint ring 411. Tighten to a torque of 23 Nm.
Table 21:
Lubricant level
Size
M
[mm]
50-220
40
50-222
65-170