5.3.1.6 Preparing the pump set
Fastening the claw for guide wire, single guide rail and guide hoop arrangement
2563:103
732
550.35
914.05
17 Nm
Fig. 13:
Fastening the claw
for guide wire, single guide
rail and guide hoop
arrangement
1. Fasten claw 732 with screw 914.05 and disc 550.35 to the discharge flange (see
drawing). Tighten the screw to a torque of 17 Nm.
Fastening the claw for twin guide rail arrangement
Fig. 14:
Fastening the claw
for twin guide rail
arrangement
1. Fasten claw 732 with screws 914, nuts 920 and discs 550 to the discharge flange
(see illustration). Tighten the screws to a torque of 70 Nm.
2. Fit profile seal 410 in the groove of the claw.
This will seal the duckfoot bend/pump connection.
Attaching the lifting chain/lifting rope
U
G
1
8
0
3
3
7
0
Attaching the lifting
chain/lifting rope for
stationary wet installation
Stationary wet installation
1.
Attach the lifting chain with shackle or the lifting rope to the recess in the pump
handle opposite the discharge nozzle. This attachment point achieves a forward
inclination of the pump set towards the discharge nozzle, which allows the pump
claw to hook onto the duckfoot bend.
U
G
1
8
0
3
3
7
0
Attaching the lifting
chain/lifting rope for
transportable wet
installation
Transportable wet installation
1.
Attach the lifting chain with shackle or the lifting rope to the recess in the pump
handle on the discharge nozzle side of the pump set. This attachment point
achieves an upright position of the pump set.