2.9.1 Repair
Special regulations apply to repair work on explosion-proof pumps. Modifications or
alterations of the pump set can affect explosion protection and are only permitted
after consultation with the manufacturer.
Repair work at the flameproof joints must only be performed in accordance with the
manufacturer's instructions. Repair to the values in tables 1 and 2 of EN 60079-1 is
not permitted.