5 Installation at Site
35 of 84
Amarex N
2563.84/08-EN
5.4.2 Electrical connection
DANGER
Electrical connection work by unqualified personnel
Risk of fatal injury due to electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof models, EN 60079.
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
CAUTION
Improper routing of power cable
Damage to the power cables!
▷
Never move the power cables at temperatures below - 25
℃
.
▷
Never kink or crush the power cables.
▷
Never lift the pump set by the power cables.
▷
Adjust the length of the power cables to the site requirements.
CAUTION
Motor overload
Damage to the motor!
▷
Protect the motor by a thermal time-lag overload protection device in
accordance with IEC 60947 and local regulations.
For electrical connection observe the wiring diagrams in the Annex and the
information for planning the control system.
The pump set is supplied complete with power cable. Always connect all marked
conductors.
DANGER
Incorrect wiring
Explosion hazard!
▷
The connection point of the cable ends must be located outside of the
potentially explosive atmosphere or inside electrical equipment approved to
equipment category II2G.
DANGER
Operating an incompletely connected pump set
Explosion hazard!
Damage to the pump set!
▷
Never start up a pump set with incompletely connected power connection
cables or non-operational monitoring devices.