5 Installation at Site
27 of 72
Ama-Drainer-Box
410.02 Profile seal
591
Collecting tank or
level-adjusting piece (not included in the scope of supply)
8)
5.
Apply a sufficient amount of lubricant to the end of level-adjustable extension
13-21. Fit it in the collecting tank.
6.
Adjust the level-adjustable extension to the floor level by inserting it further
into the collecting tank.
NOTE
Insert cover plate 68-3 into the extension to protect the tank interior against dirt.
Fig. 15:
Installed underfloor box (example)
5.3.6 Fitting the sealing collar
The sealing collar provides a moisture barrier, e.g. by polymer sealing sheets, for wet
areas without water exerting a constant hydrostatic pressure. Sealing collars are not
included in the scope of supply.
Sealing collar DF 400
1.
Place sealing collar 3 with O-ring 7 onto tank neck 8 and level it.
2.
The sealing collar is encased in concrete so that its upper edge is flush with floor
plate 4.
Take care to backfill any voids under the sealing collar.
3.
Roll out sealing sheet 2, cut it to length in the area of the tank edge and put it
into place.
4.
Glue the sealing collar and sealing sheet together using a permanently elastic
adhesive bonding and sealing compound.
8)
For Ama-Drainer-Box Z2 U only