![KSB Ama-Drainer-Box Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/ksb/ama-drainer-box/ama-drainer-box_operating-manual_2006544020.webp)
5 Installation at Site
20 of 72
Ama-Drainer-Box
1
2
3
4
Fig. 5:
Connecting the piping (at the example of 1 U)
1
Provisional cover 185
2
Inlet line
3
Vent line
4
Emergency drain (optional)
The vent line can simultaneously be used for venting and as a cable duct for the
pump power cables and control cables.
Alternatively, free DN 50/ DN 70/ DN 100 connection nozzles are available for
connecting a separate conduit.
Box 1 U
NOTE
Optional: additional PG 36 cable gland for a conduit of 24 mm diameter. Only
suitable for Ama-Drainer ... SE (single-phase AC drive).
Fig. 6:
Marking at connection 4
1.
Cut the additional connection (4) open as marked with a 48 mm diameter hole
saw.
(
ð
Section 9.2.1, Page 58)
2.
Debur the hole.
3.
Insert supplied cable gland 826 with a joint ring into the hole. Fasten it from the
inside with the nut.
CAUTION
Line too angled
Feeding in a draw wire (fish tape) is too difficult or impossible!
▷
Lay pipes with maximum angles of 30°.