5 Installation at Site
24 of 72
Ama-Drainer-Box
5.3.3 Fitting the level-adjusting piece or the puddle flange with level-adjusting piece
(not included in the scope of supply)
Box Z2 U
1
2
3
4
5
6
7
UG1322144_ZD2_F02
Fig. 9:
Fitting the level-adjusting piece
1
Extension 13-21
2
Profile seal 410.02
3
Level-adjusting piece (accessory)
7)
4
O-Ring 421.01
5
Collecting tank 591
6
Screw (12) 900.01
7
Disc (12) 550.01
5.3.4 Fitting MK 400 and MK 630 puddle flanges (not included in the scope of
supply)
Sealing against water exerting a constant hydrostatic pressure
Box 1 U
Special measures are required for fitting the MK 400 puddle flange. Manufacture the
base from waterproof concrete ("white tank").
Use a puddle flange to seal the pipe passages through the "white tank".
Box 2 ZU
Installation of the MK 630 puddle flange additionally requires the level-adjusting
piece (H = 300 mm). The level-adjusting piece is included in the accessories for the
MK 630 puddle flange.
NOTE
Measures required to ensure pressure-sealed pipe entry through the baseplate need
to be taken on site.
NOTE
If the level of groundwater exerting a constant hydrostatic pressure is >3 m, the
white tank must be equipped with a hermetically sealed waterproof concrete
substructure in the area of the lifting unit. Formwork is required.
Installation
ü
Smooth, non-porous and clean surface.
ü
Concrete cover of at least 50 mm.
ü
Use of waterproof concrete.
1.
Fit strap 3.
2.
Slide on puddle flange 2 by hand.
3.
Fit strap 3.
4.
Position the puddle flange in the centre of floor plate 1.
5.
Tighten straps 3.