Special equipment
112
Pos : 31.41 / BA/Sonderauss tatung/Eas yC ut / AM M ähwer ke/Q uerför der er/H ydrauli k Öls tands kontrolle Bild EC 9140 @ 10\ mod_1222335761098_78. doc @ 140606
Figure 69
Pos : 31.42 /Ü berschrif ten/Ü berschrif ten 3/ K-O/ Öl kontr olle @ 0\ mod_1197021908190_78. doc @ 16120
14.10.3
Checking the oil level
Pos : 31.43 / BA/Sonderauss tatung/Eas yC ut / AM M ähwer ke/Q uerför der er/H ydrauli k-Ölst ands kontroll e @ 10\ mod_1222335584255_78. doc @ 140585
Check the hydraulic oil level after every 10 operating hours of the cross conveyor.
To do this:
•
Lower the machine and switch off the engine.
•
Unscrew and remove the ventilation filter (2) (with measuring rod).
•
• Use a lint-free cloth to clean the ventilation filter (2) and insert it again completely.
•
Pull out the ventilation filter (2) again.
•
The oil level must lie between the min. and max. mark.
•
Top off with hydraulic oil if necessary.
•
Screw in and tighten the ventilation filter (2).
Pos : 31.44 /Ü berschrif ten/Ü berschrif ten 3/ K-O/ Öl wec hs el @ 0\ mod_1197021941955_78. doc @ 16139
14.10.4
Oil change
Pos : 31.45 / BA/Sonderauss tatung/Eas yC ut / AM M ähwer ke/Q uerför der er/H ydrauli k-Öl wec hs el @ 10\ mod_1222335966973_78.doc @ 140673
Change the hydraulic oil every 500 hours (but at least once a year).
•
Unscrew and remove the ventilation filter (2) (with measuring rod).
•
Screw out the oil drain plug (3).
•
Collect the used oil in a suitable drip pan.
•
Screw in the oil drain plug (3).
•
Top up oil (2) (the oil level must lie between the min. and max. mark).
•
Screw in and tighten the ventilation filter (2).
Pos : 31.46 / BA/-----Seit enumbruc h------ @ 0\ mod_1196175311226_0. doc @ 4165