COMMISSIONING / OPERATION
3
27
VFC 200
www.krohne.com
06/2019 - 4005059401 - AD VFC200 PB-PA R01 en
How to read the mapping table above:
•
If e.g. the diagnosis event bit of "Event group" "C
C
C
C
–
Sensor
Sensor
Sensor
Sensor" (59) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Function check
Function check
Function check
Function check"
(42) will be set additionally.
•
If e.g. the diagnosis event bit of "Event group" "M
M
M
M
–
Sensor
Sensor
Sensor
Sensor" (67) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Maintenance
Maintenance
Maintenance
Maintenance
required
required
required
required" (37) will be set additionally.
•
If e.g. the diagnosis event bit of "Event group" "S
S
S
S
–
Sensor
Sensor
Sensor
Sensor" (71) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Maintenance
Maintenance
Maintenance
Maintenance
demanded
demanded
demanded
demanded" (41) will be set additionally.
•
If e.g. the diagnosis event bit of "Event group" "F
F
F
F
–
Sensor
Sensor
Sensor
Sensor" (63) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Maintenance
Maintenance
Maintenance
Maintenance
alarm
alarm
alarm
alarm" (40) will be set additionally.
X
:
Corresponding DIAGNOSIS bit is set to 1 if status occured
(C)
:
If "Function Check" selected (Display C6.4.4.2 or DTM .. / EDD ..)
(M)
:
If "Maintenance Request" selected (Display C6.4.4.2 or DTM .. / EDD ..)
(S)
:
If "Out of Specification" selected (Display C6.4.4.2 or DTM .. / EDD ..)
(F)
:
If "Failure" selected (Display C6.4.4.2 or DTM .. / EDD ..)
(I)
:
If "Information" selected (Display C6.4.4.2 or DTM .. / EDD ..) bit "More diagnosis available" will only be set
within Diagnosis
()
:
If "NONE" selected (Display C6.4.4.2 or DTM .. / EDD ..) no bit will be set neither within Diagnosis nor within
Diagnosis_Extension
Event Group 13: is fixed to "Information"
Event Group 8: will not be displayed within PROFIBUS Diagnosis / Diagnosis_Extension
Event Group 9: will not be displayed within PROFIBUS Diagnosis / Diagnosis_Extension
INFORMATION!
If "Event Group 13: Config.- Operation Info" is classified as "INFORMATION" then it cannot be set
within DIAGNOSIS_EXTENSION / DIAGNOSIS.