8
TECHNICAL DATA
86
H250
www.krohne.com
04/2009 - 4000269302 MA H250-R02
H250U - Vertical installation position
Flow direction from top to bottom
Measuring span 10 : 1; flow values 100%
Reference condition:
Water 20
°
C
Air 20
°
C - 1.013 bar abs.
Remarks:
•
The indicated pressure losses are valid for water and air at maximum flow rate.
•
Other flow ranges on request.
•
Conversion to other media or operating data in accordance with VDE /VDI Directive 3513
EN
ASME
Cone
Flow rate
Water [l/h]
Flow rate
Air [Nm
3
/h]
Pressure loss
[mbar]
DN15
½
"
K 15.1
65
1.6
175
K 15.2
110
2.5
178
K 15.3
170
4
180
K 15.4
260
6
200
K 15.5
420
10
220
K 15.6
650
16
290
K 15.7
1100
28
520
K 15.8
1500
40
840
DN25
1"
K 25.1
1150
30
97
K 25.2
1800
45
85
K 25.3
2700
70
92
K 25.4
4500
120
115
K 25.5
7600
200
172
DN50
2"
K 55.1
9000
240
220
K 55.2
15000
400
230
K 55.3
21000
550
240
MA_H250_R02_en_PRT.book Page 86 Tuesday, September 22, 2009 12:26 PM