![KROHNE H250/C Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/krohne/h250-c/h250-c_handbook_2004239039.webp)
ELECTRICAL CONNECTIONS
4
39
H250
www.krohne.com
04/2009 - 4000269302 MA H250-R02
4.4.4 Switching output B2 as a pulse output
Pulse output B2 is a passive "open collector" output which is electrically isolated from the
current output and output B1. It can be operated as a low-resistance output or as a NAMUR
output.
The pulse width t
on
can be configured from 30...500 ms in the menu of the indicator.
INFORMATION!
When switching output B2 is used as a pulse output, two separate signal circuits are required.
Each signal circuit requires its own power supply.
The total resistance
3
must be adapted so that the total current I
tot
does not exceed 100 mA.
Figure 4-12: Electrical pulse output
1
Terminal B2
2
Terminal I
3
Load e.g. counter
4
Flow rate measurement 4...20 mA
5
Pulse output power supply
6
M10 power supply
Figure 4-13: Daten Pulsausgang
1
f
max
= 10 Hz
2
t
ein
3
t
aus
MA_H250_R02_en_PRT.book Page 39 Tuesday, September 22, 2009 12:26 PM