8.3 Cleaning the automatic spray gun
WARNING!
Risk of injury due to improper cleaning!
–
Adhere to the safety data sheets of the cleaning product manufacturer.
–
Do not fully immerse the automatic spray gun in a cleaning product.
1.
Chapter 7.6 ‘Shutting down’ on page 26
2.
Switch off the system and secure it against being switched on again.
3.
Connect cleaning product to fluid input.
For design with circulation connection (optional), connect the fluid circulation line.
4.
Switch on the compressed air supply.
5.
Where applicable, switch on fluid pressure pump or pressure container for cleaning
product.
6.
Begin the spray process by switching on the control air (connection "St") and the atomiser
air (connection "Z").
7.
Spray until the cleaning product runs clear.
8.
Interrupt the cleaning product supply.
9.
Blow out cleaning product residue by briefly switching on the control air.
10.
Switch off the compressed air supply and secure it against restart.
11.
Clean the outside of the device with a cloth dipped in cleaning product.
12.
Chapter 8.4 ‘Changing the fluid nozzle and the air nozzle’
) and clean with a soft brush. Do not use hard or sharp-edged objects. We rec-
ommend our brush set. See the last page for contact information.
13.
Slightly grease sliding parts with special Krautzberger grease.
The special grease can be purchased from Krautzberger GmbH (contact data see last
page).
Automatic spray gun A 10
ENGLISH
■
200-0148
GB–29
Содержание 200-0148
Страница 48: ......