8.6 Changing the needle seals
Removing the needle seals
1.
CAUTION!
Risk of injury due to material needles!
Chapter 8.5 ‘Changing the material needle’ on page 30
).
Fig. 9: Removing the needle seals
2.
Unscrew needle guide ( Fig. 9/2) from the main element ( Fig. 9/5).
3.
Unscrew seals ( Fig. 9/1 and 3) from the needle guide ( Fig. 9/2).
4.
Check the condition of the seals ( Fig. 9/1 and 3) and replace if necessary. Pay attention to
the correct installation position.
5.
Remove the flat seal ( Fig. 9/4), check condition and replace if necessary.
Inserting the needle seals
1.
WARNING!
Risk of injury through the use of incorrect spare parts!
Position the flat seal ( Fig. 9/4) onto the needle guide ( Fig. 9/2).
2.
Reinsert the mounted needle guide ( Fig. 9/2) with the two new seals ( Fig. 9/1 and 3) and
the flat seal ( Fig. 9/4) into the main element.
3.
Reinstall material needle (
Chapter 8.5 ‘Changing the material needle’ on page 30
).
Operating instructions
T-Dok-015-GB-Rev.0
[email protected], www.krautzberger.com
GB–32