44
The
FA 60 216 90
intermediate corner piece can be fitted:
Onto FA 60 211 30 and FA 60 211 50 posts using an M12 x 45 mm bolt
and an M12 washer (provided with the posts). This component can be fitted
onto either of the two holes located on the sides of the shoulder at the top
of the post.
To a concrete floor using 3 chemical anchors (one in the middle and 2 at
the ends).
FA 60 216 90
ENERGY ABSORBER
The
FA 60 202 00
energy absorber attaches to the end piece with a shackle.
Make sure the shackle tightening screw head faces upwards. Apply some
thread lock.
FA 60 202 00
CRIMPED TENSIONER
Introduce the cable into the FA 60 203 00 crimped tensioner sleeve.
At least 100 mm of cable must be fed into the tube. Mark the cable to
check the length introduced into the tube. If the length measured is the
minimum length required, reintroduce the cable into the tube. Using the
crimping tool, start crimping at point 1 by positioning the crimper jaws
in the centre of the crimp markers on the tensioner. Continue crimping
in the direction indicated on the drawing until you have finished crimp
No. 6. Rotate the crimping tube by 45° between crimps to prevent it from
becoming deformed over its length. Refer to the crimping machine user
instructions before commencing. When you have finished crimping, apply
coloured lacquer to the cable and tube which will act as an indicator in case
the cable slips inside the tube.
Particular care must be taken when carrying out this operation as it cannot
be reversed and it is central to the strength of the system and the safety
of its users.
FA 60 203 00
Unscrew both ends of the tensioner. Take care not to exceed the maximum
permitted opening distance (508 mm) of the tensioner by distributing the
length equally between the ends of the tensioner body;
this equates to
approximately 55 mm of visible thread either side of the tensioner body
(distance X). Fit the FA 60 203 00 tensioner to the FA 60 202 00 absorber
using the shackle. Make sure the tightening screw head faces upwards.
Apply some thread lock.
x
x
X ≤ 55 mm