Kramer Electronics Ltd.
VS-622DT
– Technical Specifications
51
Environmenta
l Conditions
Operating Temperature
0° to +40°C (32° to 104°F)
Storage Temperature
-40° to +70°C (-40° to 158°F)
Humidity
10% to 90%, RHL non-condensing
Regulatory
Compliance
Safety
CE
Environmental
RoHs, WEEE
Enclosure
Size
19”, 1U
Type
Aluminum
Cooling
Fan ventilation
General
Net Dimensions (W, D, H)
43.6cm x 23.7cm x 4.4cm
(17.2" x 9.3" x 1.7" )
Shipping Dimensions (W, D, H)
52.5cm x 33cm x 10.7cm
(20.7" x 13" x 4.2" )
Net Weight
2.6kg (5.7lbs) approx.
Shipping Weight
3.7kg (8.2lbs) approx.
Accessories
Included
Power Cord
Specifications are subject to change without notice at
Default Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII Protocol 3000
Example (Route input 1 to output 1):
#ROUTE 1,1,1<cr>
Ethernet
IP Address:
192.168.1.39
Default UDP Port #:
50000
Subnet mask:
255.255.0.0
Default TCP Port #:
5000
Default gateway:
192.168.0.1
Max. UDP ports:
70
Max. TCP ports:
10
Full Factory Reset
Front panel buttons:
Power off the device, press and hold the RESET button for 3 seconds
while powering the device, and then release.
Protocol 3000:
“#FACTORY” command followed by #RESET command.
Web Pages:
In the Device Settings page, General tab, click Factory reset.
Amplifier Values
Amplifier output mode:
Lo-Z
Speaker output from:
OUT 1
Web pages Authentication
User name:
Admin
Password:
Admin