Kramer Electronics Ltd.
VS-622DT
– Protocol 3000
61
HDCP-MOD
Functions
Permission
Transparency
Set:
HDCP-MOD
Administrator
Public
Get
HDCP-MOD?
End User
Public
Description
Syntax
Set:
Set HDCP mode
#HDCP-MOD
SP
inp_id,mode
CR
Get:
Get HDCP mode
#
HDCP-MOD?
SP
inp_id
CR
Response
Set/get:
~nn
@HDCP-MOD
SP
inp_id,mode
CR LF
Parameters
inp_id
– input number:
1
(IN 1),
2
(IN 2),
3
(IN 3),
4
(IN 4),
5
(IN 5),
6
(IN 6)
mode
– HDCP mode:
0
(HDCP Off),
1
(HDCP On)
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was
received.
Response is sent to all com ports after execution if HDCP-MOD was set by any other external
control device (button press, device menu and similar) or HDCP mode changed.
Notes
Set HDCP working mode on the device input:
HDCP supported
– HDCP_ON (default)
HDCP not supported
– HDCP OFF
HDCP supports changes following a detected sink - MIRROR OUTPUT
K-Config Example
Set the input HDCP-MODE of IN 1 to Off:
“#HDCP
-
MOD 1,0”,0x0D