Kramer Electronics Ltd.
VS-622DT
– Protocol 3000
71
REMOTE-INFO
Command Name
Permission
Transparency
Set:
Get:
REMOTE-INFO?
End User
Public
Description
Syntax
Set:
Get:
Get connected Step-in
module info
#
REMOTE-INFO?
SP
stage,stage_id
CR
Response
Get:
~nn
@REMOTE-INFO
SP
stage,stage_id,connected,model_name,curr_input,capabilities,num_of_inputs
,num_of_ctl_btn,type1,type2…
typeN
CR LF
Parameters
stage
– 0 (input),
stage_id
– for inputs:
1
(Input 1),
2
(Input 2),
3
(Input 3),
4
(Input 4),
5
(Input 5),
6
(Input 6)
connected
– 0 (Disconnected),
1
(Connected)
model_name
– model name string
curr_input
–
1
to
6
(Input, currently chosen on step-in module)
capabilities
–
1
(Supports Step-in),
0
(Does not support Step-in)
num_of_inputs
– number of inputs on step-in module
num_of_ctl_btn
– number of control buttons on step-in module
type1, type2… typeN
–
input type (on step-in module):
0
(Undefined),
1
(DVI),
2
(HDMI),
3
(DisplayPort),
4
(HDBaseT),
5
(SDI),
6
(VGA),
7
(DGKat)
Notes
The GET command identifies input switching on Step-in clients
The SET command is for remote input switching on Step-in clients (essentially via by the Web)
This is a legacy command. New Step-in modules support the ROUTE command
K-Config Example
Get the remote info of the step-in device (DIP-30) that is connected to input 3:
“#
REMOTE-INFO 0,3
”,0x0D