Kramer Electronics Ltd.
VS-622DT
– Protocol 3000
86
IR-STOP
Command Name
Permission
Transparency
Set:
IR-STOP
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Send IR stop command to port
#IR-STOP
SP
PortNum,Cmdid,CmdName
CR
Get:
-
-
Response
~nn@
IR-STOP
SP
PortNum,Cmdid,CmdName,Status
CR LF
Parameters
Port_Num
–
1
(IR port 1),
2
(IR port 2),
3
(IR port 3),
4
(IR port 4),
*
(broadcasts to all ports)
Cmd_id
–
serial number of command for flow control and response commands from device
CommandName
– a string, the alias of the IR command. The controlling device is responsible for
sending the correct name
Status
–
0
(Sent),
1
(Stop),
2
(Done),
3
(Busy),
4
(Wrong Parameter),
5
(Nothing to Stop),
6
(Start),
7
(Timeout),
8
(Error)
K-Config Example
Send IR stop command to IR Port 2:
“#IR
-
STOP 2,1,power”,0x0D
RELAY-STATE
Command Name
Permission
Transparency
Set:
RELAY-STATE
End User
Public
Get:
RELAY-STATE?
End User
Public
Description
Syntax
Set:
Set relay state
#RELAY-
STATE
SP
RelayNumber,RelayState
CR
Get:
Get relay state
#RELAY-STATE?
SP
RelayNumber
CR
Response
~nn@
RELAY-STATE
SP
RelayNum,RelayState
CR LF
Parameters
RelayNumber
–
1
(Relay 1),
2
(Relay 2)
RelayState
–
0
(open),
1
(close)
K-Config Example
Set relay 2 to closed:
“#RELAY
-
STATE 2,1”,0x0D