Feature 

Function 

12V DC 

+12V DC connector for powering the unit 

RS-232 COM 1

 Port 

Connects to the RS-232 9-pin D-sub port on the Kramer (or 

other) device 1 or PC  

ETHERNET

 Port 

Connects to your LAN  

RS-232 COM 2

 Port 

Connects to the RS-232 9-pin D-sub port on a Kramer (or 

other) device 2 or PC 

A Kramer device can be connected to either the RS-232 COM 2 

port, or to the RS-485 terminal block port (but not to both) 

RS-485 

Terminal 

Block Port 

Connects to the RS-485 port on a Kramer (or other) device 

A Kramer device can be connected to either the RS-232 COM 2 

port, or to the RS-485 terminal block port (but not to both) 

PIN A connects to the “A” (+) PIN; PIN B connects to the “B” 

(–) PIN (and PIN G connects to the “G (Ground)” PIN, if 

necessary) 

The connection to G is usually not necessary for RS-485 

STATUS COM 1

 LEDs  Lit when a signal is transmitted or received from port 1 

(mostly used for troubleshooting) 

STATUS COM 2

 LEDs  Lit when a signal is transmitted or received from port 2 

(mostly used for troubleshooting) 

ON

 LED 

Lit when receiving power 

RESET

 Button 

Press to reset the machine 

Turns the machine off and on again while retaining its definitions 

(identical to disconnecting the power adapter and then connecting 

it again) 

10 

RS-485 TERM. 

Button  Press for BUS termination: 

Set to OFF if the RS-485 terminal block port is not connected 

Set to ON if the RS-485 terminal block port is connected 

11 

FACTORY RESET 

Button

 

Press to reset to factory default definitions 

First disconnect the power adapter and then connect it again while 

pressing the FACTORY RESET button. The unit will power up and 

load its memory with the factory default definitions 

12 

PROG

 Switch 

Switch ON to upgrade firmware 

13 

CONFIG 

Switch 

Not used, set to OFF 

im Vertrieb von            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание FC-10ETH

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL FC 10ETH Ethernet Controller P N 2900 000086 Rev 2 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 2: ...1 Downloading from the Internet 19 6 2 Connecting the PC to the RS 232 Port 19 6 3 Upgrading Firmware 20 7 Technical Specifications 21 Figures UFigure 1 FC 10ETH Ethernet ControllerU 5 UFigure 2 Unde...

Страница 3: ...x Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Conne...

Страница 4: ...rver or workstation of data HTML pages or e mails that is sent in packets across the Internet Every device connected to an IP network must have a unique IP address This address is used to reference th...

Страница 5: ...se only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference...

Страница 6: ...settings network settings serial settings and destination device settings Supports easy dial up and Internet system remote control requiring only a dedicated IP address and a modem in the remote loca...

Страница 7: ...Virtual null modem connection which you can emulate over the Ethernet or Internet Can be created in any quantity on your PC and does not occupy an actual serial port 3 1 Defining the FC 10ETH Etherne...

Страница 8: ...Lit when a signal is transmitted or received from port 1 mostly used for troubleshooting 7 STATUS COM 2 LEDs Lit when a signal is transmitted or received from port 2 mostly used for troubleshooting 8...

Страница 9: ...ork hub switch or router using a straight through cable see USection 4 1 2U 4 1 1 18BConnecting the ETHERNET Port Directly to a PC Crossover Cable You can connect the Ethernet port of the FC 10ETH to...

Страница 10: ...utton see Figure 3 Figure 3 Local Area Connection Properties Window 6 Select Use the following IP Address and fill in the details as shown in Figure 4 7 Click OK Figure 4 Internet Protocol TCP IP Prop...

Страница 11: ...following 1 Connect the FC 10ETH as described in USection 4 2U see UFigure 5U 2 Insert the CD ROM in the CD ROM drive double click the Setup exe file and follow the on screen instructions 3 Click the...

Страница 12: ...er Figure 5 Connecting the FC 10ETH for Configuration 4 2 1 The Kramer Configuration Manager Window Figure 6 FC 10ETH Configuration Manager Window im Vertrieb von CAMBOARD Electronics www camboard de...

Страница 13: ...n FC 10ETH device in the Ethernet or Internet Port a pre assigned address of the destination FC 10ETH device that provides a direct route to its Transport layer The Destination Settings area is active...

Страница 14: ...ng 1 Press the Search button to find the device connected to the PC 2 Set the IP address number according to your network requirements 3 Clear the Active Mode check box if selected in the configuratio...

Страница 15: ...ller 13 4 Set the Destin IP and Port in the Destination Settings Area for CHANNEL 1 and CHANNEL 2 5 Press the Config button to accept changes im Vertrieb von CAMBOARD Electronics www camboard de Tel 0...

Страница 16: ...that is connect the RS 232 COM 1 port of the FC 10ETH to the RS 232 port of your Kramer non Kramer machine 1 via a Null modem COM 2 port of the FC 10ETH to the RS 232 port of your Kramer non Kramer ma...

Страница 17: ...ting the FC 10ETH in the Passive Routing Mode 5 1 1 24BSetting a Virtual Port If the control application cannot work with an Ethernet driver download the Kramer VSPM from our Web site to set a virtual...

Страница 18: ...nect the adapter to the mains electricity 2 Configure the FC 10ETH A to the Passive routing mode see Section 4 3 1 3 Disconnect unit A Unit A is configured to the Passive mode 4 Connect the FC 10ETH B...

Страница 19: ...it B Connect the RS 485 terminal block of the serial controller 1 to the RS 485 terminal block port on the FC 10ETH B Alternatively you can connect an RS 232 output terminal block of the serial contro...

Страница 20: ...lling Machines via the Ethernet using the FC 10ETH Figure 9 Connecting the FC 10ETH in the Active Routing Mode im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce...

Страница 21: ...h_11 zip from the technical support section 2 Extract the file fc10eth_11 zip package which includes the KFR Programmer application setup and the s19 firmware file to a folder for example C Program Fi...

Страница 22: ...mer Window 2 Select the required COM Port to which the FC 10ETH is connected on your PC 3 Press the File button to select the s19 firmware file included in the package 4 Press the Send button to downl...

Страница 23: ...COLS ICMP ARP ping TCP UDP POWER SOURCE 12 VDC 80mA DIMENSIONS 12cm x 7 5cm x 2 5cm 4 7 x 2 95 x 0 98 W D H WEIGHT 0 3kg 0 25lbs approx ACCESSORIES Power supply mounting bracket OPTIONS RK 3T 19 rack...

Страница 24: ...instructions supplied withtheproduct iii Repair orattemptedrepairby anyone not authorized by Kramer iv Any shipment of theproduct claims must bepresentedtothe carrier v Removal orinstallation of thepr...

Страница 25: ...P N 2900 000086 Rev 2 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Отзывы: