Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
manner that vent termination will be placed between two studs, eliminating the need for additional framing.
Follow vent pipe manufacturer’s installation instructions for horizontal terminations. Include
required 3” (76mm) top clearance and 1” (25mm) sides and bottom clearances for approved
rigid vent systems and the Kozy Heat #800-1 series flexible vent system.
HORIZONTAL TERMINATIONS
Follow vent pipe manufacturer’s installation instructions for vertical terminations. A minimum 1” (25mm) clearance on all sid
es of
vertical vent pipe must be maintained.
VERTICAL TERMINATIONS
FRAMING
If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is being used, a
lintel must be used over the top of fireplace to support the added weight.
See-Thru applications: #617 Lintel Iron
Pier applications: #788-T Lintel Iron
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
MINIMUM HORIZONTAL FRAMING DIMENSIONS
VENT PIPE TOP (A)
NAT. GAS
LP GAS
RIGID PIPE
48-
1/8” (1222mm)
52-
3/4” (1340mm)
KOZY HEAT #800-1 SERIES FLEX PIPE
54-
1/2” (1384mm)
54-
1/2” (1384mm)
Frame a 12-
1/2” (318mm) high (H) x 10
-
7/8” (276mm) wide (W) opening on exterior wall
for chimney termination. This opening size includes required 3” (76mm) at top and
1” (25mm) at sides and bottom for rigid vent systems and Kozy Heat #800
-1 series flex vent
systems.
10-7/8”
(276mm)
12-1/2”
(318mm)
IMPORTANT
Restrictor (included) required for all vertical terminations. See page 14 for installation instructions.
IMPORTANT
Vent cap location must be in compliance with guidelines on page 19 of this manual
.
WARNING
Install fireplace on hard metal or wood surface extending the full width and depth of fireplace.
Minimum platform size: 38-3/4” (984mm) wide x
24” (610mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.
IMPORTANT
Horizontal Vent Heat Shield must be installed when using a 90
˚
elbow to horizontally position the vent system or when using
#800-1 Series Kozy Heat flexible vent system for horizontal terminations. See page 11 for installation instructions.
Kozy Heat wall thimble pass-thru (#800-WPT or #800-WPT2) must be used on all horizontal vent runs.
Follow instructions on page 11.
NOTE
Consider height of hearth finish material (stone, brick, etc.) when building fireplace platform. The bottom of fireplace must be
level with finished hearth to allow for lower grill operation and proper fit of optional decorative full door faces.
Figure 9a