SAFETY INFORMATION                           

 

Installation  and  repair  should  be  done  only  by  a  qualified  service  person.  The  appliance  should  be  inspected  by  a  
qualified service person before use. Annual inspection by a qualified service person is required to maintain warranty. 
More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative 
that  control  compartments,  burners  and  circulation  air  passageways  of  the  appliance  be  kept  clean.  

If  this  appliance  is  installed  directly  on  carpeting,  tile  or  other  combustible  material  other  than  wood  flooring,  the  
appliance  shall  be  installed  on  a  metal  or  wood  panel  extending  the  full  width  and  depth  of  the  appliance.  

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns 
or clothing ignition.  

Young  children  should  be  carefully  supervised  when  they  are  in  the  same  room  as  the  appliance.  Toddlers,  young  
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at 
risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, 
young children and other at risk individuals out of the room and away from hot surfaces.   

Clothing or other flammable material should not be placed on or near the appliance. 

Adequate accessibility clearances for servicing and proper operation must be maintained.   

This appliance must not share or be connected to a chimney flue serving any other appliance.   

Keep area around the appliance clear of combustible materials, gasoline and other flammable vapor and liquids.  

The flow of combustion and ventilation air must not be obstructed. 

  

Due  to  high  temperatures  the  appliance  should  be  located  out  of  traffic  and  away  from  furniture  and  draperies. 

The  glass  front  or  any  part  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 
Work should be done by a qualified service technician.   

Clean glass only when cool and only with non-abrasive cleansers.   

WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED 
OR  BROKEN.  REPLACEMENT  OF  THE  GLASS  SHOULD  ONLY  BE  PERFORMED  BY  A  LICENSED  OR  
QUALIFIED SERVICE PERSON . 

The glass assembly, Part #TMT-057T,  shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc. 
DO NOT SUBSTITUTE MATERIALS.   

Do not strike or slam glass assembly.   

Any  safety  screen  or  guard  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 

Under  no  circumstances  should  any  solid  fuel  (wood,  coal,  paper  or  cardboard  etc.)  be  used  in  this  appliance. 

Keep burner and control compartment clean. 

 

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this 
appliance  and  to  replace  any  part  of  the  control  system  and  any  gas  control  which  has  been  under  water. 

This fireplace has been tested by OMNI-Test Laboratories, Portland, Oregon and complies with:  
 
ANSI  Z21.88-2009/CSA 2.33-2009, “Standard for Vented Gas Fireplace Heaters.”   
CAN/CGA 2.17-M91 (R2009), “Gas-Fired for Use at High Altitudes.”    
CAN/CSA P.4.1-09, “Testing Method for Measuring Annual Efficiency”. 

 

 
This  installation  must  conform  with  local  codes,  or  in  the  absence  of  local  codes,  with  the 

National  Fuel  Gas  Code,  ANSI  Z223.1/NFPA  54,  

or the 

Natural Gas and Propane Installation Code, CSA B149.1    

   

Содержание TMT-3875

Страница 1: ...e or explosion may result causing property damage personal injury or loss of life WARNING This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile hom...

Страница 2: ...bility but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong Dudley Hussong Presid...

Страница 3: ...TS Mantel Requirements 12 GLASS FRAME ASSEMBLY Glass Frame Assembly Removal Removal 12 GAS LINE CONNECTION Gas Line Connection 13 VENTING Approved Venting 14 Restrictor 14 Elbows 14 Horizontal Vent Sy...

Страница 4: ...erials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located out of traffic and away...

Страница 5: ...appliance or equipment The sign shall read in print no less the one half inch 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side...

Страница 6: ...10 64 F 7 7 8 200mm G 12 305mm I 2 1 2 64mm H 8 1 4 210mm E 11 1 2 292mm A 34 1 2 876mm D 26 660mm B 38 3 4 984mm C 24 610mm SPECIFICATIONS WARNING All stand off brackets must be attached to fireplace...

Страница 7: ...3 4 298mm Mantel 12 305mm deep from top of fireplace 12 305mm SEE THRU PIER WARNING All stand off brackets must be attached to fireplace Do not remove Top stand off brackets are not load bearing Non c...

Страница 8: ...s point 10 Install facing material mantel or cabinetry allowing room for optional full face doors if applicable 11 Install logs 12 Install grills and optional decorative doors faces 13 Verify proper o...

Страница 9: ...gh holes located in fireplace bottom PREPARE THE FIREPLACE BEND AT PERFORATIONS REMOVE SCREWS FRAMING STUD NAILING FLANGE INSTALLED BEND AT PERFORATION STAND OFF ASSEMBLY INSTALLATION Stand off bracke...

Страница 10: ...00 1 SERIES FLEX PIPE 54 1 2 1384mm 54 1 2 1384mm Frame a 12 1 2 318mm high H x 10 7 8 276mm wide W opening on exterior wall for chimney termination This opening size includes required 3 76mm at top a...

Страница 11: ...for wall covering thickness and fireplace facing materials If using a hearth adjust rough opening size as necessary to maintain at least the minimum clearance requirements Overall finished depth is 24...

Страница 12: ...on marked 1 3 8 10mm flange into framed opening Secure to interior wall with screws not provided C From the exterior place insulation between flange and top of framed opening in wall pass thru section...

Страница 13: ...dles out and down to release glass frame assembly bottom 3 Pull top handles out and up to release glass frame assembly top 4 Remove glass frame assembly from fireplace INSTALL GLASS FRAME ASSEMBLY Pul...

Страница 14: ...with a 3 8 10mm x 18 457mm long flexible gas connector and manual shut off valve The gas line should be run to the point of connection where the shut off valve and flexible gas line will connect The a...

Страница 15: ...e subtracted from maximum allowed venting For each 45 elbow used 1 1 2ft 457mm must be subtracted from maximum allowed venting ELBOWS NOTE 2 45 degree elbows may be used in place of 1 90 elbow IMPORTA...

Страница 16: ...67m VERTICAL TERMINATIONS NAT LP GAS Termination Cap Min 6 152mm Max 10ft 3 048m 90 Elbow Illustration shown with minimum horizontal for NAT gas WARNING KOZY HEAT WALL PASS THRU PART 800 WPT 4 1 2 114...

Страница 17: ...ional elbow used after first elbow 3ft 914mm must be subtracted from maximum venting allowed For each 45 elbow used 1 1 2ft 457mm must be subtracted from maximum venting allowed 2 45 degree elbows may...

Страница 18: ...e D Secure with 3 evenly spaced screws ILLUSTRATION ON FOLLOWING PAGE 4 Place a bead of sealant outside 5 flex pipe collar C end with EXTERNAL lip sliding it inside 5 pipe on top of fireplace D Secure...

Страница 19: ...ure 18a A G E C H B HOT A TERMINATION BOX B SLOTS IN EXTERIOR WALL PLATE C 5 FLEX PIPE COLLAR D 5 PIPE ON FIREPLACE OR EXTENSION KIT E 8 FLEX PIPE COLLAR F 8 PIPE ON FIREPLACE OR EXTENSION KIT G VINYL...

Страница 20: ...any other appliance CANADA 12 305mm US 9 229mm K Mechanical air supply inlet CANADA 6ft 1 83m US 3ft 914mm above if within 10ft 3 05m horizontally Massachusetts installations 10ft 3 05m L Above paved...

Страница 21: ...er 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27 Over 20 12 to 21 12 8 0 2 44 VENT TERMINATION CLEARANCES Figure 20a CAUTION This appliance must not be connected to or joined with any chimney f...

Страница 22: ...conversion kit securing with nuts 4 removed in step 3 9 Position hooks on frame included with kit over mounting studs located along top and bottom sides of pier end frame 10 Attach upper hood included...

Страница 23: ...r TM1 TM3 TM3 TM2 TM2 TM5 TM5 TM4 TM4 NOTE Logs are installed in numerical order Log numbers are located on bottom of each log Refer to following instructions and illustrations for proper placement CA...

Страница 24: ...T INSTALLATION Position 2 TM6 and 2 TM7 logs aligning to notches in base logs TM7 TM7 TM6 TM6 Use a steel or stiff bristle nylon brush to distribute Rock Wool Embers onto logs and burner Figure 23b Fi...

Страница 25: ...urner and or pilot have been burning use appropriate protection to avoid burns or damage to personal property before removing any components Figure 24a PILOT PLATE RE CONNECT REMOTE THERMOSTAT WIRES R...

Страница 26: ...ach end of grill Secure to lower grill opening 1 Align hooks in upper louver to slots located in fireplace face Set down into position 2 Insert upper hood flange into clips located at top of upper air...

Страница 27: ...necessary FINALIZING THE INSTALLATION RESTRICTOR USAGE Turn fireplace on and allow to burn for 15 minutes If flames indicate there is excessive draft flickering short flames a restrictor may be neces...

Страница 28: ...black tips the burner tube venturi may need adjustment BURNER TUBE VENTURI ADJUSTMENT GUIDELINES VENTURI POSITION FLAME COLOR VENTURI ADJUSTMENT Closed too far Dark orange flame with black tips Open v...

Страница 29: ...S AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN Annual examination of venting system by a qualified agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INST...

Страница 30: ...in material or workmanship at Hussong Manufacturing Co Inc s expense including reasonable labor costs to repair or replace the defective component if a factory pre authorization is given for the repa...

Страница 31: ...he time of this Lifetime Warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufacturing Co Inc may fully discharge...

Страница 32: ...life WARNING WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to fireplace installation manual and this manual For assistance or ad...

Страница 33: ...Installation 4 THERMOSTAT WALL SWITCH REMOTE Thermostat Wall Switch Remote 5 OPERATING INSTRUCTIONS Valve and Pilot Assembly Components 6 Lighting and Shutdown Instructions 7 9 Pressure Testing 10 TR...

Страница 34: ...erials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located out of traffic and away...

Страница 35: ...kPa MANIFOLD PRESSURE LO 1 1 WC 27 kPa 6 3 WC 1 57 kPa ORIFICE SIZE 30 45 INPUT BTU hr kW 47 000 13 77 kW 46 000 13 48 kW MINIMUM INPUT BTU hr kW 23 500 6 89 kW 26 500 7 77 kW PART NUMBER DESCRIPTION...

Страница 36: ...e control switch to a warmer location under firebox to turn fan ON sooner or move it to a cooler location under firebox to turn fan ON later The fan will turn on when sensor in temperature control swi...

Страница 37: ...d cover included with remote control must be placed over remote receiver to prevent overheating NOTE Fireplace must be turned ON and OFF by same method For example If fireplace is turned ON by remote...

Страница 38: ...6 VALVE PILOT ASSEMBLY COMPONENTS ELECTRODE PILOT HOOD THERMOPILE THERMOCOUPLE VALVE TERMINALS GAS CONTROL KNOB PIEZO IGNITOR HI LO FLAME ADJUSTMENT KNOB ON OFF ROCKER SWITCH Figure 6a...

Страница 39: ...PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHT...

Страница 40: ...gas go to next step 10 Push gas control knob in slightly and turn counterclockwise to ON The burner can now be turned ON by depressing ON OFF rocker switch located beside valve or wall switch OR by s...

Страница 41: ...has a HI LO flame adjustment knob designed to allow you to tailor the look and heat output of your fireplace Adjust by turning middle knob on gas control valve ADJUSTING FLAME HEIGHT TURN BURNER OFF...

Страница 42: ...s rocker switch to ON and note manometer reading 6 Press rocker switch to OFF 7 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Attach manometer to man...

Страница 43: ...LIGHTING INSTRUCTIONS A Check that pilot flame impinges on thermocouple Clean and or adjust pilot for maximum flame impingement B Ensure thermocouple connection at gas valve is fully inserted and tig...

Страница 44: ...If burner lights wires are faulty or connections are bad BURNER WILL NOT LIGHT FREQUENT PILOT OUTAGES A Pilot shield not installed B Pilot flame too high or too low causing pilot safety to drop out C...

Страница 45: ...pitch on horizontal vent 1 4 6mm rise per foot is required on horizontal venting E Inner vent pipe leaking exhaust gases back into firebox Check for leaks Repair if necessary F Improper vent cap insta...

Страница 46: ...urer s instructions supplied with the kit Refer to appliance owner s manual or product data plate for proper inlet and manifold pressure adjustments and orifice sizing OCK S30B NAT GAS CONVERSION KIT...

Страница 47: ...INGS NAT 1 8 3mm open 9 position L P 5 8 16mm open 1 position Secure with screw previously removed keeping in mind Venturi may need further adjustment depending on your specific venting configuration...

Страница 48: ...d professional service technician Figure 16a Lazy yellow flames ideal Short blue flames venturi open too far Dark orange flames black tips Venturi closed too far Excessive burner media Lifting ghostin...

Страница 49: ...venting system by a qualified agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL INSTALLATION The flow of combustion and ven...

Страница 50: ...8 Pilot Generator Thermocouple Nat Gas 700 230 Natural Gas Orifice 30 700 089 Pilot Generator Thermocouple LP Gas 700 245 LP Gas Orifice 45 700 090 Piezo Igniter w Nut no wire OCK S30B Natural Gas Con...

Страница 51: ...personal injury or loss of life WARNING WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to fireplace installation manual and this...

Страница 52: ...CHEMATICS Wiring Schematics 4 OPERATING INSTRUCTIONS Control System Components 5 6 System Operations 7 10 Lighting and Shutdown 11 12 Pressure Testing 13 Error Codes 14 TROUBLESHOOTING Troubleshooting...

Страница 53: ...erials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located out of traffic and away...

Страница 54: ...c Grill Assembly 2 sets TMT 028 IPI IPI Fan Kit 700 308 Remote Control TMT 3875 IPI NATURAL GAS LP GAS MINIMUM INLET GAS PRESSURE 5 WC 1 25 kPa 7 WC 1 74 kPa recommended 11 WC 2 74 kPa recommended MAX...

Страница 55: ...QUIRES ELECTRICITY 120V AND OR BATTERIES TO OPERATE USING BATTERY BACK UP WILL OPERATE BURNER ONLY FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER Figure 4a To Fan To Lights Pilot...

Страница 56: ...S Figure 5a Pilot Igniter Flame Sensor PILOT ASSEMBLY REMOTE CONTROL Figure 5c GAS VALVE Outlet pressure tap Stepper motor Pilot connection orange Main valve connection green Inlet pressure tap Pilot...

Страница 57: ...6 CONTROL SYSTEM COMPONENTS FAN CONTROL MODULE Figure 6a RECEIVER DFC CONTROL BOARD Figure 6c Figure 6b...

Страница 58: ...and set to the particular code of that transmitter 5 Push OFF button on transmitter The receiver will beep two 2 times to indicate the transmitter s command is again accepted 6 Move slider switch to R...

Страница 59: ...t level To activate this function press the Thermostat Key The LCD display will change to show the room thermostat is ON and set temperature is now displayed To adjust set temperature press Up or Down...

Страница 60: ...Arrow Key to turn light kit on press Down Arrow Key to turn light kit off A single beep will confirm reception of the command 3 Use the installed dimmer switch to adjust brightness of lights ACCENT L...

Страница 61: ...ansmitter mode button to adjust settings The thermostat and burner ON OFF operating functions will not work on the transmitter LOW BATTERY DETECTION TRANSMITTER Remote control battery lifespan depends...

Страница 62: ...TION THIS IS NORMAL AND DOES NOT AFFECT THE PERFORMANCE OR LONGEVITY OF THE FIREPLACE 1 This appliance is equipped with an ignition device which automatically lights the pilot DO NOT try to light the...

Страница 63: ...to the appliance 5 Press hand held remote ON button TO TURN GAS OFF TO APPLIANCE 1 Press hand held remote OFF button 2 Turn OFF all electric power to appliance if service is to be performed 3 Manual...

Страница 64: ...CAN CAUSE DELAYED IGNITION 1 Loosen inlet IN pressure tap screw counter clockwise 2 Attach manometer using a 5 16 I D hose 3 Set IPI CPI switch to CPI setting 4 Light pilot Note manometer reading 5 Mo...

Страница 65: ...ON OFF BUTTON 1 Press ON OFF button on transmitter to turn system off 2 After 2 seconds press ON OFF button on transmitter again The DFC Board will reset and restart the ignition sequence RESET SYSTEM...

Страница 66: ...pressure Consult with plumber or gas supplier No LP in tank Check LP propane tank Refill if necessary Wiring disconnection Use wiring schematic in this manual to determine that all wiring connections...

Страница 67: ...FF BURNER Improper venturi setting Venturi may need to be closed slightly Improper vent cap installation Check for proper vent cap installation Blockage or vent system leaks NO REACTION TO COMMAND Rec...

Страница 68: ...e installation is not proper and complete until operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit Refer to appliance owner s manual...

Страница 69: ...er whether field or factory made 7 Test inlet pressure Visually check pilot flame Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition To Adjust pilot Turn p...

Страница 70: ...ng Gas pressure too high Correct pilot flame Figure 19b BURNER TUBE VENTURI ADJUSTMENT GUIDELINES VENTURI POSITION FLAME COLOR VENTURI ADJUSTMENT Closed too far Dark orange flame with black tips Open...

Страница 71: ...venting system by a qualified agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL INSTALLATION The flow of combustion and ven...

Страница 72: ...mbly LP Gas NCK TMT S Natural Gas Conversion Kit 700 308R Receiver LCK TMT S LP Gas Conversion Kit 700 558 GTMFS Wire Harness TMT 135 Burner Assembly 700 130 Fan Control Module TMT 043 Pilot Shield 70...

Страница 73: ...of life WARNING WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to fireplace installation manual and this manual For assistance or...

Страница 74: ...SCHEMATICS Wiring Schematics 4 OPERATING INSTRUCTIONS Control System Components 5 6 System Operations 7 9 Lighting and Shutdown Instructions 10 12 Pressure Testing 13 TROUBLESHOOTING Troubleshooting...

Страница 75: ...erials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located out of traffic and away...

Страница 76: ...Grill Assembly 2 sets TMT 028 IPI IPI Fan Kit 700 308 Remote Control TMT 3875 MV NATURAL GAS LP GAS MINIMUM INLET GAS PRESSURE 5 WC 1 25 kPa 7 WC 1 74 kPa recommended 11 WC 2 74 kPa recommended MAXIMU...

Страница 77: ...ELECTRICITY 120V AND OR BATTERIES TO OPERATE USING BATTERY BACK UP WILL OPERATE BURNER ONLY FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER Figure 4a To Fan To Lights Pilot Assemb...

Страница 78: ...EM COMPONENTS Figure 5a REMOTE CONTROL Valve Terminals Gas Control Knob Step Motor Pilot Hood Thermopile Thermocouple PILOT ASSEMBLY Figure 5c Electrode GAS VALVE Manifold Pressure Tab Inlet Pressure...

Страница 79: ...Using the end of a paper clip or other similar object press button through hole marked PRG on receiver front cover Receiver will beep three 3 times to indicate it is ready to synchronize with a transm...

Страница 80: ...the Thermostat Key The LCD display will change to show the room thermostat is ON and set temperature is now displayed To adjust set temperature press Up or Down arrow keys until desired set temperatu...

Страница 81: ...The auxiliary function controls the AUX power outlet on the Fan control module which in turn controls the light kit 1 Use MODE key to guide you to AUX icon 2 Press Up Arrow Key to turn light kit on p...

Страница 82: ...umber of ignitions changes to room thermostat set point etc When transmitter batteries are low a Battery Icon will appear on the LCD display before all battery power is lost When batteries are replace...

Страница 83: ...PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGH...

Страница 84: ...n below If you don t smell gas go to next step 9 Turn on all electric power to appliance 10 Push gas control knob in slightly and turn counterclockwise to ON 11 Move receiver switch to REMOTE position...

Страница 85: ...ol knob to OFF DO NOT FORCE TURN BURNER OFF TURN PILOT OFF NOTE The pilot will stay lit NOTE This control valve has an interlock device If pilot has been turned off it cannot be relit until thermocoup...

Страница 86: ...Press hand held remote ON button and note manometer reading 6 Press hand held remote OFF button 7 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Atta...

Страница 87: ...pressure Consult with plumber or gas supplier No LP in tank Check LP propane tank Refill if necessary Wiring disconnection Use wiring schematic in this manual to determine that all wiring connections...

Страница 88: ...G Improper log placement Refer to corresponding pages in this installation manual Improper venturi setting Venturi may need to be opened slightly to allow more air into the gas mix Improper pitch on h...

Страница 89: ...The installation is not proper and complete until operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit Refer to appliance owner s manua...

Страница 90: ...er whether field or factory made 7 Test inlet pressure Visually check pilot flame Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition To Adjust pilot Turn p...

Страница 91: ...Gas pressure too high Correct pilot flame Figure 18b FACTORY SET BURNER TUBE VENTURI SETTINGS ADJUST AS NECESSARY FOR YOUR INSTALLATION NATURAL GAS LP PROPANE GAS 1 8 3mm open 9 position 5 8 16mm ope...

Страница 92: ...venting system by a qualified agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL INSTALLATION The flow of combustion and ven...

Страница 93: ...otor LP Gas TMT 701 Control Board LP Gas 700 203 Manual Shut off Valve 700 084 SIT MV Valve Natural 700 213B 18 Flexible Gas Line Black 700 085 SIT MV Valve LP 700 226 Flexible Gas Line Valve to Burne...

Отзывы: