14
Refer to the vent systems manufacturer's installation manual for complete installation instructions.
Installation must conform with the venting requirements and restrictions as outlined in this manual.
Simpson Dura-Vent DV-GS 5” x 8” direct vent system (horizontal and vertical terminations).
Ameri-Vent Direct Chimney System 5” x 8” (horizontal and vertical terminations).
Selkirk Model DT Direct Vent Chimney Systems 5” x 8” (horizontal and vertical terminations).
Metal Fab Chimney System: 5” x 8” (horizontal and vertical terminations).
Kozy Heat #800-1 series flexible vent system (horizontal terminations).
ICC EXCELDirect Direct Vent Chimney Systems 5” x 8” (horizontal and vertical terminations).
BDM 5” x 8” Direct Vent Chimney System (horizontal and vertical terminations).
This fireplace is designed to be used with any of the above vent systems without the use of an additional adaptor.
VENTING
APPROVED VENTING
For each additional 90° elbow used after first elbow, 3ft. (914mm) must be subtracted from maximum allowed venting.
For each 45° elbow used, 1-1/2ft. (457mm) must be subtracted from maximum allowed venting.
ELBOWS
NOTE
(2) 45° degree elbows may be used in place of (1) 90° elbow.
IMPORTANT
Consult the local and national installation codes to assure adequate combustion and ventilation air is available.
RESTRICTOR INSTALLATION
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
installation is complete a restrictor may be required or may need to be removed or modified.
Page 26 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting
is completed.
RESTRICTOR
Slide restrictor into exhaust pipe on top of fireplace with tabs
pointing towards you prior to attaching venting.
IMPORTANT
WE RECOMMEND INSTALLING A RESTRICTOR (INCLUDED IN THE FIREPLACE COMPONENTS PACKET) ON
ALL VERTICAL VENT TERMINATIONS INSTALLED WITHOUT ELBOWS.
Large Restrictor
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
Remove tab (s) to
create small restrictor
Figure 14a