Troubleshooting 

Burner 

lights when 

pilot only 

should light 

Yes  

Pilot 

holds 

flame? 

No  

1.   Verify transmitter is not powered on or in thermostat mode calling 
for heat.  Display should say OFF next to thermometer  image on 
display for thermo off.  
2.   Verify receiver switch is not in ON position 
3.   Ensure all electrical connections are secure based on the wiring 
diagram 
4.   Verify proper voltage at the main valve connection ( EV2 green).  
See page 15. 
 

- If voltage is present replace IFC board 

 

- If voltage is not present replace gas valve (solenoid not 

 

closing) 

1.   Check that the continuous pilot switch is ON (down position) 
2.   Verify pilot flame makes full contact with flame sensor 
 

-  Verify gas pressure on full capacity 

 

-  Verify turbulence is not pushing flame off flame sensor 

3.   Clean the flame sensor and inspect wiring for damage 
4.   Verify pilot assembly is properly grounded and pilot hood is 
brushed clean of debris and securely pressed down.   
5.    Replace flame sensor 
6.    Check voltage at pilot valve connection (EV1 orange) See page 15 
 

-  If no voltage present when calling for pilot, replace IFC 

board 
 

-  If voltage is present, replace gas valve (valve not       

 

   opening) 

Main 

burner 

ignites? 

No  

1.   Verify the receiver switch is in ON position 
 

-  If in the REMOTE position verify remote is powered ON 

and thermostat is OFF.   
2.   Verify electrical connections are properly connected according to 
the wiring diagram and replace any damaged harnesses 
3.   Verify the pilot flame is properly directed to ignite the burner 
4.   Verify piezo is not sparking if so, go back to Piezo Still Sparking 
5.   Verify proper components are installed for type of gas used 
6.   Check continuity of the main burner coil.  See pg 16 
7.   Check for voltage at the main burner connection (EV2 green) See 
page 16 
 

-  If voltage is present replace gas valve (not opening) 

 

-  If no voltage is present replace IFC board 

No  

Yes  

Main burn-

er remains 

on 

No  

1.   Verify the receiver switch is in ON position 
 

-  If in REMOTE, verify remote ON and thermostat says OFF 

2.   Verify electrical components are properly connected according to 
the wiring diagram and replace any damaged harnesses 
3.   Verify pilot flame makes contact with flame sensor.  Clean flame 
sensor of any debris or silicone film.   
4.   Verify gas pressure on full capacity is according to manual 
5.   Check for voltage at the main burner connection (EV2 green) See 
page 16 
 

-  If voltage is present when drops out, replace gas valve 

 

-  If no voltage, replace IFC board 

Yes  

3  

2  

Yes  

Содержание SIT Proflame II

Страница 1: ...ation will assist you through this process Kozy Heat welcomes your questions while you are at the job site 800 253 4904 This guide is ONLY intended for professional or trained technicians June 2012 R1...

Страница 2: ...2 System Overview The primary components that are included in the SIT Proflame II GTMFS System Gas Valve Integrated Fireplace Control IFC SIT Pilot Assembly Transmitter remote control GTMF model...

Страница 3: ...o 1 0VDC test image shown on pg 16 Gas Pressure Very Important for the Function of an IPI Pilot Assembly Inlet Pressure Test Point Measures amount of gas coming into the valve NG 5 0 WC to 7 0 WC LP 1...

Страница 4: ...ower loss Testing Power Voltage AC Power Pins red and black would be about 6 5VAC See test images on pg 15 Diagnostic LEDs This area contains LEDs which provides the technician with lockout codes For...

Страница 5: ...me into two for burner and flame sensor Igniter provides spark to the pilot hood Flame Sensor Rectifies the pilot is lit and carries the voltage to the IFC module to stop spark ing and allow main burn...

Страница 6: ...e batteries begin to wear down the blue backlight feature on the remote will deactivate indicating the batteries as beginning to lower Approximately after this happens the homeowner has about 2 3 week...

Страница 7: ...th ability to manually set the flame height OFF Thermostat is off but will operate manually from remote using ON OFF key SMART Works just the same as ON thermostat but the SMART function will modulate...

Страница 8: ...hermostat Key and the Mode Key at the same time Continuous Pilot Intermittent Pilot CPI IPI This system has the option of a continuous standing pilot feature By having the pilot on continuously the fi...

Страница 9: ...approximately 2 seconds press it again Reset Using the Remote Flame Adjustment buttons In the manual mode use the down arrow to lower the flame all the way to OFF Wait 2 seconds and then use the up a...

Страница 10: ...n a lockout position See page 9 on lockout and reset information Press the Red SW1 button the on the IFC module You should hear 3 fast beeps indicating the receiver box is ready to learn the remote co...

Страница 11: ...oper grounding 6 Check continuity of valve coil Image on pg 16 If no continuity replace valve 8 Verify proper voltage at pilot valve connection Image on pg 15 If voltage is present and no gas released...

Страница 12: ...gas valve valve not opening Main burner ignites No 1 Verify the receiver switch is in ON position If in the REMOTE position verify remote is powered ON and thermostat is OFF 2 Verify electrical connec...

Страница 13: ...rify the ON OFF rocker switch is in the ON position 3 Verify there is power at the outlet the fan plugs into 4 Verify the remote does not say OFF on remote Note Fan in thermo settings is time delay 5...

Страница 14: ...etting 0VAC out of this test make sure the POWER switch is in the ON position and if so test the outlet the unit is plugged into for power Note This test will be a VAC reading Figure 1 3 would be the...

Страница 15: ...4 292VDC Figure 2 1 and drop to about 0 940 Figure 2 2 This reading tells us the IFC module is sending power through the harness to open the corresponding solenoid If you are getting power and valve i...

Страница 16: ...ition and disconnect the wiring harness from EV1 and EV2 Using one multimeter pin on the solenoid and the other on the ground your reading should be approximately 331 4 ohms Same process is conducted...

Страница 17: ...timeter would need to be in the Ohms position and disconnect wiring harness from the step motor to expose the leads Using a multimeter place the two pins on the two leads of the connector Your reading...

Страница 18: ...would need to be in the DC voltage position Using one multimeter pin on the black lead and the other on the white lead your reading should be approximately 118 VDC on HI Same process is conducted for...

Страница 19: ...19 Battery Pack 885 Proflame Flame Sensor Main ON OFF Switch Pilot Burner Igniter Pilot SW1 Button red IFC Control Module Appliance Ground Star Main Line Variable Speed Fan Variable Lights...