Page 1
SAFETY TESTING
The corn/pellet stove, Model #OLV-PC ‘Olivia’, has been tested and certified by OMNI-Test Laboratories,
Inc., Beaverton, Oregon, to comply with ASTM E1509-04, ULC-C1482, ULC-S627 ‘Tested & Certified Room
Heater, Pellet Fuel-Burning Type’. Also for use in Mobile Homes. Installation must conform with
applicable requirements of NFPA 211, and applicable building & mechanical codes. In Canada,
installation must conform with the CAN/CSA B365 , Installation Code for Solid Fuel Burning Appliances
and Equipment and applicable building codes.
SAFETY & INSTALLATION PRECAUTIONS
‚
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
‚
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
‚
This stove’s exhaust system operates under negative pressure in the combustion chamber and
positive pressure in the chimney. It is imperative that the vent system used on this stove is properly
installed and airtight. Do not install a damper in the exhaust system of this stove.
‚
Smoke detectors installed in the same room as this stove may activate if smoke from the firebox if
allowed to enter the room or if the ash drawer is smoking when it is emptied.
‚
When installed in a manufactured home:
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME
FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
‚
CANADIAN INSTALLATIONS: Clearances may only be reduced by means approved by the regulatory
authority.
‚
Contact the local building official to obtain a permit and information on any local installation
restrictions and inspection requirements.
‚
This stove is approved for U.S. & Canadian conventional & mobile home installations.
VENT SYSTEM REQUIREMENTS
‚
Type ‘L’ vent systems must be used. Follow vent manufacturer’s clearance requirements. Refer to
local building codes, appliance and vent system manufacturer’s instructions for precautions required
when passing through a combustible wall or ceiling.
‚
This stove utilizes 3" exhaust pipe. Use the appropriate adaptor for proper connection to the 3"
exhaust collar at the back of the stove.
‚
Outside air is
required
for proper operation of this stove. The connection at the back of the stove is 2"
O.D. Use the appropriate adaptor to properly reduce the outside air pipe for connection at the back
of the stove.