VENTING TERMINATION REQUIREMENTS:
MAXIMUM HORIZONTAL RUN: 9 FT.
MAXIMUM VERTICAL RUN: 36 FT.
Determine the best location for the vent termination cap. Items to consider:
‚
Distances from air inlets - Installation must comply with the requirements in this installation manual, the
requirements of the vent system you are using and local building codes.
‚
Prevailing winds - When terminating where prevailing winds would blow against the termination cap, sporadic
operation of this stove may result which may include excessive smoking inside the firebox.
‚
Location of adjacent structures - Installation must comply with the requirements in this installation manual,
the requirements of the vent system you are using and local building codes.
‚
Local code requirements - Check local building codes for additional requirements and/or restrictions
concerning installation of a corn / pellet burning stove.
Exhaust must terminate above the combustion air inlet.
Do not terminate vent in any enclosed or semi-enclosed area (i.e. Garage, Attic, Crawl space, etc.) or any area
which would build up a concentration of fumes.
Vent surface can get hot enough to cause burns if touched by children. Use non-combustible guards or shields if
necessary.
Combustion air must be connected to an outside source and not drawn from the indoor living environment,
garage, attics, crawl spaces and the like.