Model #OLV-PC Olivia

Corn / Pellet Stove

INSTALLATION MANUAL

Please read this entire manual before installation and use of the corn / pellet fuel burning  room heater.

Failure to follow these instructions could result in property damage, bodily injury or even death.

This stove must only be installed with factory approved and tested components.   Use of components not 

tested and approved for use with this stove or using another manufacturer’s components may
 

result in a fire or safety hazard and voids all warranty. 

Contact local building or fire officials about restrictions and 

installation inspection requirements in your area.

SAVE THESE INSTRUCTIONS

 

June 2006 (2)

Содержание OLV-PC OLIVIA

Страница 1: ...e bodily injury or even death This stove must only be installed with factory approved and tested components Use of components not tested and approved for use with this stove or using another manufactu...

Страница 2: ...ustrations 8 Venting Termination Requirements 9 Minimum Clearance Locations from Exhaust Terminations 10 Combustion Air Requirements 11 Electrical Components Wiring Schematic 12 Thermostat Installatio...

Страница 3: ...e may activate if smoke from the firebox if allowed to enter the room or if the ash drawer is smoking when it is emptied When installed in a manufactured home CAUTION THE STRUCTURAL INTEGRITY OF THE M...

Страница 4: ...m vertical rise of 3 feet above the stove exhaust connection Failure to provide adequate natural draft vertical rise may result in smoke being released into the house when electricity to the stove is...

Страница 5: ...rigid sections of pipe Wall Thimble 45o Elbow 90o Elbow Ceiling Support Firestop Spacer Square Horizontal Cap Round Horizontal Cap Attic Insulation Shield Used for installations that pass through an a...

Страница 6: ...ct to Direct Temp vent system Pellet Stove Termination Adapter Used in conjunction with horizontal Tee with Tee cap exit cap decorative cap or vertical cap Decorative Cone Cap Exit Cap 45o Horizontal...

Страница 7: ...tove and use highly volatile fuel or combustible material in this stove 2 WARNING DO NOT INSTALL IN A SLEEPING ROOM 3 CAUTION THE STRUCTURAL INTEGRITY OF THE FLOORS WALLS CEILINGS AND ROOF MUST BE MAI...

Страница 8: ...23 5 8 Center of intake collar from right side 12 1 2 Center of intake collar from left side 9 1 2 Center of intake collar from floor 7 3 8 Center of exhaust collar from right side 9 1 2 Center of ex...

Страница 9: ...Front from faceplate 6 Floor protection from sides from door opening 3 Floor protection from back of stove Must extend to wall if vent system horizontally exits thru wall Must extend under tee if ver...

Страница 10: ...Termination 1 Horizontal Termination 2 Typical Corner Installation Vertical Installation 1 Vertical Installation 2 Note Not recommended for cold climate installations Floor protection extends 6 in fro...

Страница 11: ...Installation must comply with the requirements in this installation manual the requirements of the vent system you are using and local building codes Local code requirements Check local building codes...

Страница 12: ...es i e fences adjacent buildings protruding parts of the structure roof eaves or overhangs plants shrubs 24 610 mm 5 Below a door window cavity or air vent 4 1 2 m 6 Horizontally from a door window ca...

Страница 13: ...or bend the aluminum flex pipe with too small a radius as this will block the flow of combustion air and result in poor operation of the stove Use of a hood for protection against wind and weather is...

Страница 14: ...n operation Run the power cord to the nearest outlet Do not allow fan cord to come in contact with any hot or sharp surfaces on the stove When this stove is installed in a mobile home it must be elect...

Страница 15: ...reaches the thermostat set temperature the stove will automatically operate at the lowest setting 1 THERMOSTAT HOOK UP 1 Install the thermostat by connecting the wires from the thermostat to the exte...

Страница 16: ...column reading on the manometer NOTE The reading should be 10 w c or more negative pressure Once draft is established the reading will be 0 24 w c or higher negative pressure IMPORTANT The negative p...

Страница 17: ...tallation Products made by other manufactures are NOT covered by this Limited Warranty regardless of whether they were purchase with the fireplace or later added No person is authorized to extend the...