1. Remove screw securing burner at back wall of firebox. Lift right
side of burner up to release from burner orifice. Remove burner from firebox.
2. Install (4) halogen bulbs. (Included in components packet).
3. Reinstall burner assembly, making sure venturi is positioned around burner orifice.
Secure burner to back wall with screw previously removed.
FIREGLASS INSTALLATION
(purchased separately)
CONTEMPORARY FRAME INSTALLATION
(purchased separately)
NOTE: Contemporary frame must have 1/4” (6 mm) clearance on top for removal from fireplace.
Align hooks in contemporary frame to corresponding slots in fireplace. Insert hooks into slots
required depth needed to accommodate facing material (up to 1/2” (13 mm) thick).
#NCL-LK NICOLLET LIGHT KIT
PAGE 21
CAUTION: Disconnect all electrical power from fireplace before performing this task.
ATTENTION: If converting to LP (propane) gas, do so now before installing light kit components. Follow instructions included with conversion kit.
NOTE: To avoid damage and prolong the life of halogen bulbs, never touch with bare hands. Always use a soft cloth when handling.
Install fireglass onto burner assembly and pilot shield, being careful not to block pilot assembly.
WARNING: Do not block pilot assembly with fireglass. A blocked pilot assembly may result in a delayed ignition.
ATTENTION: Do not operate this fireplace without face frame installed. Various finishes are available. See Dealer for details.
DO NOT BLOCK THIS AREA
ATTENTION: Do not operate this fireplace without fireglass installed. Various colors available. See Dealer for details.
Содержание Nicollet NCL-195
Страница 43: ...PAGE 42...
Страница 44: ...PAGE 43...