HORIZONTAL & VERTICAL COMBINATION
VENTING
PAGE 18
MINIMUM AND MAXIMUM VERTICAL VENTING
NOTE: Horizontal sections require 1/4” (6 mm) rise for every 12” (305 mm) of travel.
TERMINATION
CAP
MINIMUM 3 ft. (914 mm)
MAXIMUM 36 ft. (10.97 m)
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED WHEN USING A 90-DEGREE ELBOW TO
HORIZONTALLY POSITION VENT SYSTEM.
IMPORTANT: KOZY HEAT WALL PASS-THRU, PART #800-WPT (4-1/2” (114 mm) - 6-1/2” (165 mm) ) WALL THICKNESS OR
#800-WPT2 (6-1/2” (165 mm) - 12-1/2” (318 mm) ), MUST BE USED ON ALL HORIZONTAL VENT RUNS.
24
26
28
30
40
38
36
34
32
10 12 14 16 18 20 22 24 26 28 30
(6.1m)
(6.1
m)
HORIZONTAL / VERTICAL COMBINATION:
(6.10m) 20' Vertical
(6.10m) 20' Horizontal
Termination must be
within shaded area
(ft.) 0
2
4
6
8
10
12
14
16
20
22
18
0 2 4 6 8
(12.9m)
(9.1
4m)