This fireplace is manufactured for use with Natural Gas. An LP conversion kit (#OCK-A60L-IPI),  is included with this fireplace.  
Follow instructions included with conversion kit if converting to LP gas. 

 

#NCL-195 

NATURAL GAS 

LP GAS 

MINIMUM INLET GAS PRESSURE 

5.0 inches W.C.  (7.0 W.C. recommended) 

11.0 inches W.C.  (recommended) 

MAXIMUM INLET GAS PRESSURE 

10.5 inches W.C. 

13.0 inches W.C. 

ORIFICE SIZE 

#52 

#60 

INPUT BTU/hr. 

12,500 

12,500 

MINIMUM INPUT BTU/hr. 

4,500 

4,500 

EFFICIENCY 

66.27% 

62.15% 

AFUE 

65.20% 

60.83% 

                          GAS LINE CONNECTION                                

GAS CONVERSION

 

PAGE 13 

CAUTION:  Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.  
                      If not, follow ANSI 223.1.   
    
                      Commonwealth of Massachusetts: Installation must be done by a licensed plumber or gas fitter. 

IMPORTANT: 

 

The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating  

 

 

 

       conditions and was determined independently of any installed system.

 

NOTE: A listed (and Commonwealth of Massachusetts approved) 12” (13 mm) T- handle manual shut-off valve and flexible gas connector 
 

      (included) are connected to the 1/2” (13 mm) control valve inlet. If substituting for these components, please consult local codes for  

 

      compliance. 

 
NOTE:  This fireplace is equipped with a 3/8”(10 mm)  x 18” (457 mm) long flexible gas connector and manual shut-off valve. The gas line 

 

 

 

 

 

 

 should be run to the point of connection where the shut-off valve and flexible gas line will connect. 

 

 

 

 

 

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing 

 

 

 

 

 

       of that system at pressures in excess of ½ psi. 

 

 

 

 

 

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any  

 

 

 

 

 

 

pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa). 

 
 

 

 

       NOTE:  For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods

ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in  
 

 

 

     accordance with the requirements of the ANSI Z223.1 installation code. 

Содержание Nicollet NCL-195

Страница 1: ...ur gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions are not...

Страница 2: ...ourselves in being dedicated to not only function and reliability but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from you...

Страница 3: ...Vertical Combination Venting 14 Elbows 15 Restrictor Installation 15 VENTING cont Securing Vent System 15 Horizontal Vent Shield Installation 16 800 WPT 800 WPT 2 Wall Pass thru Installation 16 Horizo...

Страница 4: ...ear of combustible materials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located o...

Страница 5: ...tic fan kit 1 75 CFM Each unit factory tested Tested by PFS Corporation Sealed combustion chamber Intermittent or Standing pilot ignition Removable IPI board Flame sensing system safety shutoff Automa...

Страница 6: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print no less the one half inch 1 2 in size GAS...

Страница 7: ...framing at the back and both sides Framing material may touch sides of stand offs but no material is allowed between stand offs Side stand off brackets must be re positioned if installing in a Kozy H...

Страница 8: ...fireplace and venting Fireplace must be placed directly on wood or non combustible surface not linoleum or carpet extending entire depth and width of fireplace Due to high surface temperatures firepla...

Страница 9: ...o fireplace face APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS 32 5 8 829 mm High x 19 3 4 502 mm Wide x 14 7 8 378 mm Deep Header must be in the up position to maintain proper clearanc...

Страница 10: ...PASS THRU 800 WPT or 800 WPT2 MUST BE USED ON ALL HORIZONTAL VENT RUNS FOLLOW INSTRUCTIONS ON PAGE 15 OF THIS INSTALLATION MANUAL IMPORTANT THE HORIZONTAL VENT HEAT SHIELD INCLUDED WITH THIS FIREPLACE...

Страница 11: ...TOP OF UNIT TO HORIZONTALLY POSITION VENT SYSTEM TYPICAL INSTALLATION OPTIONS TYPICAL HORIZONTAL INSTALLATION TYPICAL CORNER INSTALLATION TYPICAL VERTICAL INSTALLATION NOTE Horizontal vent heat shiel...

Страница 12: ...ease glass frame assembly top D Remove glass frame assembly from fireplace A Place glass frame assembly onto fireplace front B Pull top latch out and down to secure glass frame assembly top C Pull bot...

Страница 13: ...SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER IMPORTANT If installing a fan it is easier to complete before the control board is connected to the gas line The following components must be removed from...

Страница 14: ...th of Massachusetts approved 12 13 mm T handle manual shut off valve and flexible gas connector included are connected to the 1 2 13 mm control valve inlet If substituting for these components please...

Страница 15: ...MUM 90 elbow termination cap MAXIMUM 90 elbow 20 ft 6 096 m horizontal termination cap VENTING PAGE 14 APPROVED VENTING MINIMUM VERTICAL RISE 3 ft 914 mm vertical termination cap MAXIMUM VERTICAL RISE...

Страница 16: ...installed Remove tab s to create small restrictor Slide restrictor into exhaust pipe on top of fireplace with tabs pointing towards you prior to attaching venting For each additional 90 elbow used aft...

Страница 17: ...re to exterior wall with screws not provided FRAMING DIMENSIONS FOR KOZY HEAT WALL PASS THRU KITS INSULATION HEAT SHIELD MUST BE FLUSH WITH WALL PASS THRU WARNING MAINTAIN ALL CLEARANCES AS STATED IN...

Страница 18: ...securing damper Slide damper toward front of fireplace Retighten wing nuts to secure position MAXIMUM HORIZONTAL VENTING 90 DEGREE ELBOW Wing Nuts MAXIMUM 20 ft 6 096 m TERMINATION CAP 90 DEGREE ELBOW...

Страница 19: ...LLED WHEN USING A 90 DEGREE ELBOW TO HORIZONTALLY POSITION VENT SYSTEM IMPORTANT KOZY HEAT WALL PASS THRU PART 800 WPT 4 1 2 114 mm 6 1 2 165 mm WALL THICKNESS OR 800 WPT2 6 1 2 165 mm 12 1 2 318 mm M...

Страница 20: ...above a gas meter regulator assembly within 3 ft 914 mm horizontally from the centerline of the regulator J Non mechanical air supply inlet to building or the combustion air inlet to any other applia...

Страница 21: ...ROOF PITCH X 12 H minimum MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING APPROVED CAP APPROVED VENT PIPE DISCHARGE OPENING 8 MIN IF VENT IS CLOSER THAN 8 IT MUST TERMINATE AT LEAST 2 HIGHER THA...

Страница 22: ...p to 1 2 13 mm thick NCL LK NICOLLET LIGHT KIT PAGE 21 CAUTION Disconnect all electrical power from fireplace before performing this task ATTENTION If converting to LP propane gas do so now before ins...

Страница 23: ...11 if necessary 7 Remove fireglass 8 Remove screw securing burner assembly to back wall of firebox Remove burner assembly by lifting up and to the right releasing venture from burner orifice Remove b...

Страница 24: ...y removed 4 Reinstall fireglass Page 20 5 Reconnect gas line to manual shut off valve 6 Reconnect all wiring harnesses to gas valve Plug all compo nents into electrical outlet 7 Reinstall glass frame...

Страница 25: ...T COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER PAGE 24 NCL 195 WIRING SCHEMATICS NOTE This appliance must be electrically grounded and connected in accordance with local codes or in the absen...

Страница 26: ...E SCREW STEP MOTOR WIRE HARNESS MAIN VALVE INTERNAL SOLENOID CONNECTION GREEN AND WHITE WIRES PILOT INTERNAL SOLENOID CONNECTION ORANGE AND WHITE WIRES PILOT ADJUSTMENT SCREW INLET PRESSURE SCREW OUTL...

Страница 27: ...WITCH CONTINUOUS PILOT ON OFF SWITCH LEARN BUTTON MAIN CONTROL MODULE VALVE STEP MOTOR TERMINAL COMMUNICATION LINK TO EXTENSION MODULE AC ADAPTOR CONNECTION EXTENSION MODULE COMMUNICATION LINK TO CONT...

Страница 28: ...95 REMOTE CONTROL INFORMATION CHILD PROOF ICON LIGHT LEVEL FLAME HEIGHT FAN SPEED BATTERY LIFE ICON THERMOSTAT MODE ICON SET TEMPERATURE visible only in THERMO MODE MANUAL ON OFF ROOM TEMPERATURE CONT...

Страница 29: ...front of fireplace This is the coolest location under firebox ensuring longer battery life Before matching security codes make sure 120V AC is connected and powered to fireplace and hand held remote c...

Страница 30: ...letting you know the procedure has been completed If converting from NAT to LP gas 1 one second long beep If converting from LP to Nat gas 3 three second long beep Continue with gas type conversion b...

Страница 31: ...E This remote will operate the lights allowing for 6 different light levels When LIGHT button is pressed LIGHT level setting will flash on the LCD screen Press UP or DOWN buttons to select desired lig...

Страница 32: ...f MANUAL MODE NOTE The flame height can adjust up to 6 different height levels according to amount of heat required This range however is dictated by the Flame Level setting see previous page When des...

Страница 33: ...isions for adequate combustion and ventilation air WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switches Do not try to light any appliance Do not use the phone in your building Immediately...

Страница 34: ...N If fireplace will not operate follow instructions TURNING OFF GAS TO FIREPLACE and call your service technician or the gas supplier ATTENTION This fireplace is equipped with an ignition device which...

Страница 35: ...nstructions below for proper testing procedures INLET PRESSURE TEST 1 Loosen inlet IN pressure tap screw counter clockwise 2 Attach manometer using a 1 4 I D hose 3 Light fireplace using hand held rem...

Страница 36: ...ignition What to Check Check if pilot flame is actually present when valve is turned OFF if yes replace valve Replace pilot assembly Replace module THERMAL SAFETY Overheat Protection Error Code Four...

Страница 37: ...decorative frame 6 Light fireplace Wait at least 15 minutes before determining if any further adjust ments are necessary TO ADJUST VENTURI PAGE 36 BURNER VENTURI Flame appearance is affected by severa...

Страница 38: ...d out of 5 exhaust pipe 5 Readjust exhaust damper to desired position Tighten wing nuts 6 Attach glass frame assembly and light fireplace Wait 15 minutes before determining if any further modification...

Страница 39: ...k pilot light and burner when in operation The flames should be steady not lifting or floating CONTROL BOARD SYSTEM Annual examination of the venting system by a qualified agency is required IF VENT A...

Страница 40: ...tening for a beep from receiver when ON is pressed on hand held remote If you do not hear a beep ensure main control module has learned the hand held remote See above Ensure black lead from pilot asse...

Страница 41: ...o red black to black Check functionality with all transmitters to determine if there is an issue with the main control system or an individual transmitter If the issue is with an individual transmitte...

Страница 42: ...3 Manual Shut off Valve 700 400 NCL Main Control Module 700 213 18 Flexible Gas Line Black 700 404 IPI Valve Natural LP Gas 700 226 Flexible Gas Line Valve to Burner Connection 700 199 Pilot Assembly...

Страница 43: ...PAGE 42...

Страница 44: ...PAGE 43...

Отзывы: