RESTRICTOR INSTALLATION
VENTING
PAGE 15
A restrictor is included in fireplace components packet.
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
installation is complete a restrictor may be required or may need to be removed or modified.
Page 36 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting
is completed.
RESTRICTOR
Large Restrictor
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
Remove tab (s) to create
small restrictor
Slide restrictor into exhaust pipe on top
of fireplace with tabs pointing towards
you prior to attaching venting.
For each additional 90° elbow used after first (2) elbows, 3 ft. (914 mm) must be subtracted from maximum allowed venting. For each 45°
elbow used, 1-1/2 ft. (457 mm) must be subtracted from maximum venting allowed.
NOTE: (2) 90
˚
elbows may be used within the maximum horizontal and vertical vent runs.
(2) 45° degree elbows may be used in place of (1) 90° elbow.
ELBOWS
SECURING VENT SYSTEM
1.
Bend (3) tabs on fireplace top „up‟.
2. Install first vent pipe section.
3. Secure vent pipe section to fireplace through tabs with (3) screws.
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW TO HORIZONTALLY
POSITION VENT SYSTEM.