8
SPECIFICATIONS
2.0 SPECIFICATIONS
2.1 Appliance Components
Part Number
Description
NCL-150
Control Board Assembly
700-203
Manual Gas Shut-off Valve
NCL-135
Burner Assembly
NCL-057T
Glass Frame Assembly
NCL-LKT
Light Kit
700-408
Remote Control
SL36-085
Restrictor Plate
NCL-HHS
Horizontal Vent Heat Shield
2.1.1 Additional Components Required
Refer to Section 7.0 Venting on page 20 for approved vent
systems.
2.2 Heating Specifications
Natural Gas
LP Gas
Maximum
Input Rating
12,500 Btu/h
(3.66 kW)
13,000 Btu/h
(3.81 kW)
Minimum
Input Rating
6,500 Btu/h
(1.91 kW)
6,500 Btu/h
(1.91 kW)
Manifold Pressure
(High)
3.8” WC
(0.95 kPa)
11” WC
(2.74 kPa)
Manifold Pressure
(Low)
1.1” WC
(0.27 kPa)
2.9” WC
(0.72 kPa)
Orifice Size (DMS)
#52
#60
2.2.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer
to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities,
or codes having jurisdiction in you area regarding derate
guidelines.
2.2.1.1 US Installations
Refer to the American Gas Association guidelines for the gas
designed appliances derating method. For elevations above 2,000
ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft
(305 m) above sea level.
2.2.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500 ft (1,372
m), the certified high altitude rating shall be reduced at the rate of