  OPERATING INSTRUCTIONS

WARNING

Do not operate appliance with the glass front removed, cracked, 

or broken. Replacement of the glass should be done by a licensed 

or qualified service person.
Under no circumstances should any solid fuel (wood, coal, paper, 

cardboard, etc.) be used in this appliance.
Children and adults should be alerted to the hazards of high 

surface temperature and should stay away to avoid burns or 

clothing ignition.

CAUTION

Clothing or other flammable material should not be placed on or 

near the appliance.
Young children should be carefully supervised when they are in the 

same room as the appliance. Toddlers, young children and others 

may be susceptible to accidental contact burns. A physical barrier 

is recommended if there are at risk individuals in the house. To 

restrict access to a fireplace or stove, install an adjustable safety 

gate to keep toddler, young children and other at risk individuals 

out of the room and away from hot surfaces.

WARNING: 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury, or loss of life.

1. 

STOP! Read all the safety information above on this page. 

2. 

Press the wireless remote OFF button. 

3. 

Turn off all electric power to the appliance. 

4. 

This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by 

hand.

5. 

Locate the manual valve installed by your qualified service 

technician.

6. 

Turn the manual valve clockwise 

to the OFF position. 

7. 

Wait five (5) minutes to clear out any gas. Then, smell 

for gas, including near the floor. If you smell gas, STOP! 

Follow ‘B’ in the safety information above. If you do not smell 

gas, go to the next step. 

8. 

Turn the manual valve counterclockwise  

to the ON 

position. 

9. 

Turn on all electric power to the appliance. 

10.  Press the wireless remote ON button. 
11.  If the appliance will not operate, follow the instructions, “To 

Turn Off Gas To Appliance” and call your service technician 

or gas supplier. 

OPERATING INSTRUCTIONS

NOTE

When this fireplace is initially lit, condensation will appear on the glass. This is normal in all gas fireplaces and will disappear after 
several minutes. A paint smell will occur during the first few hours of burning. It is recommended to leave the fan off during this period to 
help speed the paint curing process. This fireplace may produce noises of varying degree as it heats and cools due to metal expansion 
and contraction. This is normal, and does not affect the performance or longevity of the fireplace.

A. 

This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by 

hand. 

B. 

BEFORE OPERATING

 smell around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor. 
WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone 

in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire 

department. 

C. 

Use only your hand to turn the gas control manual valve. 

Never use tools. If the valve will not turn by hand, do not 

try to repair it; call a qualified service technician. Force or 

attempted repair may result in a fire or explosion. 

D. 

Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control that has been under water. 

ON/OFF 

ON

OFF

1. 

Press the wireless remote OFF button.

2. 

Turn off all electric power to the appliance if service is to 
be performed. 

3. 

Locate the manual valve installed by your qualified service 
technician.

4. 

Turn the manual valve clockwise 

to OFF position. 

FOR YOUR SAFETY READ BEFORE OPERATING

TO TURN OFF GAS TO APPLIANCE

10.0  OPERATING INSTRUCTIONS

Содержание NICOLLET-195S NCL-195S

Страница 1: ...RE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage This appliance may be installed in an aftermarket permanently located manufactu...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...s 20 7 4 Restrictor Assembly and Installation 20 7 5 Vertical Terminations 21 7 6 Combination Venting 22 7 7 Exhaust Damper 23 7 8 Secure Vent System 23 7 9 Horizontal Vent Heat Shield Installation 23...

Страница 6: ......

Страница 7: ...he above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the bu...

Страница 8: ...5 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 0 72 kPa Orifice Size DMS 52 60 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer to National...

Страница 9: ...Viewing Area Width Back to Vent Center Inches 31 1 2 18 1 2 5 5 16 14 3 8 1 1 2 16 15 16 11 7 8 7 3 4 Millimeters 825 470 134 365 25 12 431 301 196 Figure 2 1 NCL 195S Unit Dimensions 55 16 134mm 7 19...

Страница 10: ...ed with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with Hussong Mfg s barriers for...

Страница 11: ...a location 3 2 Floor Support and Protection The fireplace must be placed directly on a wood or non combustible surface not linoleum or carpet extending the entire depth and width of the fireplace If t...

Страница 12: ...ance top to ceiling 31 in 787 mm Appliance sides to adjacent sidewall 3 in 76 mm From appliance front 36 in 914 mm Top of appliance to 3 4 in 19mm trim 2 1 4 in 57 mm Mantel 12 in 305 mm deep from app...

Страница 13: ...thickness and fireplace facing materials If using a hearth adjust the rough opening size as necessary to maintain minimum clearance requirements If masonry is to be used optional prepare the necessary...

Страница 14: ...se for every 12 in 305 mm of travel NOTE Elbows listed with approved vent systems for this appliance vary in vertical length Please consult the vent manufacturer s instructions to determine the elbow...

Страница 15: ...FACING AND FINISHING 15 4 0 FACING AND FINISHING 4 1 Mantel Requirements Figure 4 1 Mantel and Trim Requirements 18 457mm 15 381mm 12 305mm 13 343mm 10 267mm 7 191mm 19mm 2 57mm TOP OF FIREPLACE FACE...

Страница 16: ...side the air openings 2 Align the notched tabs located on the back with the slots in the fireplace Raise slightly and push back to desired position 3 Lower the screen front until the notched tabs are...

Страница 17: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Страница 18: ...r 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27...

Страница 19: ...e combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L...

Страница 20: ...n 76 mm 1 in 25 mm 1 in 25 mm 7 2 2 Wall Pass Through Kozy Heat s 800 WPT series or wall thimble products that comply with the required 3 in 76 mm top clearance to combustibles must be installed for a...

Страница 21: ...listed as non combustible per ASTM E 136 Table 7 3 NG LPG Minimum Maximum Vertical Terminations Minimum Vertical Length Maximum Vertical Length 3 ft 914 mm 50 ft 15 2 m VENTING DIAGRAM VERTICAL TERMIN...

Страница 22: ...ble 7 4 NG LPG Minimum Horizontal Vent Terminations Minimum Vertical Rise Minimum Horizontal Run Maximum Horizontal Run 90 elbow 6 in 152 mm 20 ft 6 m Table 7 5 NG LPG Max Vertical Max Horizontal Comb...

Страница 23: ...tabs on top of the fireplace up 2 Install the first vent pipe section 3 Secure vent pipe section to fireplace through tabs with 3 screws Figure 7 3 Secured Vent System ATTACHMENT SCREWS Figure 7 4 Sec...

Страница 24: ...installing any media Follow instructions included with the gas conversion kit CAUTION Disconnect all electric power from the fireplace insert before performing any of these tasks NOTE To avoid damage...

Страница 25: ...o working on any electrical lines NOTE It easier to install the fan kit before connecting the gas line to the control board This appliance when installed must be electrically grounded in accordance wi...

Страница 26: ...side of the burner up to release from burner orifice 8 Remove halogen bulbs 9 Remove and save 7 screws securing control board 10 Lift control board out of firebox being careful not to damage sealing g...

Страница 27: ...t or remove the grounding prong from this plug 9 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes...

Страница 28: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Страница 29: ...osition for remote control operation of the main burner and fireplace features 10 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 30: ...imately 2 seconds move the switch to the ON position The ignition sequence will start again 10 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After appr...

Страница 31: ...lot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD screen wi...

Страница 32: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Страница 33: ...ode Fan s will operate at previous setting There is no delay in start up or stop time 10 8 9 Accent Light Kit The light intensity can be adjusted through 6 levels 1 Press the mode key to index to the...

Страница 34: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 35: ...ri Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 16 mm OPEN 11 2 1 1 Venturi Adjustment NOTE If soot is present on the glass check log positioning before adjusting the venturi...

Страница 36: ...strictor Installation 1 Remove the safety barrier and glass frame assembly 2 Open the exhaust damper by loosening the wing nuts to access the vent exit 3 Bend the tabs on the restrictor included in fi...

Страница 37: ...LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Страница 38: ...s Media Installation on page 24 Improper venturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 11 2 1 Burner Venturi on page 35 Incorre...

Страница 39: ...air intake system is disassembled for any reason reinstall per instructions provided with installation Refer to Section 7 0 Venting on page 20 Performed by Qualified Service Person Frequency Annually...

Страница 40: ...00 652 NG Burner Orifice 52 700 252 IFC Wire Harness Assembly 700 653 LPG Burner Orifice 60 700 260 Pilot Assembly NG 700 551 Conversion Kit NG NCK NCL S Pilot Assembly LPG 700 551 1 Conversion Kit LP...

Страница 41: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 42: ......

Страница 43: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: