1.0  INTRODUCTION

1.1  Appliance Certification

Laboratory: OMNI-Test Laboratories in Portland, Oregon 
Standards: 
ANSI Z21.88-2014/CSA 2.33-2014, Vented Gas Fireplace Heaters
CGA 2.17-M91 (R2009), Gas-Fired Appliances for Use at High 
Altitudes
This installation must conform with local codes, or in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane Installation Code, CSA 
B149.1.

1.2  Requirements for the 

Commonwealth of Massachusetts

The following requirements reference various Massachusetts 
and national codes not contained in this manual.

For all sidewall horizontally vented gas fueled equipment installed 
in every dwelling, building or structure used in whole or in part 
for residential purposes, including those owned or operated 
by the Commonwealth and where the side wall exhaust vent 
termination is less than (7) feet above finished grade in the area 
of the venting, including but not limited to decks and porches, the 
following requirements shall be satisfied:

1.2.1  Installation of Carbon 

Monoxide Detectors

At time of installation of side wall horizontally vented gas fueled 
equipment, the installing plumber or gas-fitter shall observe that 
a hard wired carbon monoxide detector with an alarm and battery 
back-up is installed on the floor level where the gas equipment is 
to be installed. In addition, the installing plumber or gas-fitter shall 
observe that a battery operated or hard wired carbon monoxide 
detector is installed on each additional level of the dwelling, 
building or structure served by the side wall horizontal vented gas 
fueled equipment. It shall be the responsibility of the property 
owner to secure the services of qualified licensed professionals 
for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled 
equipment is installed in a crawl space or attic, the hard wired 
carbon monoxide detector with alarm and battery back-up may 
be installed on the next adjacent floor level. In the event that 
the requirements of this subdivision can not be met at the time 
of completion of installation, the owner shall have a period of 
thirty (30) days to comply with the above requirements; provided, 
however, that during said thirty (30) day period, a battery 
operated carbon monoxide detector with an alarm shall be 
installed.

1.2.2  Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with 
the above provisions shall comply with NFPA 720 and be ANSI/
UL 2034 listed and IAS certified.

1.2.3  Signage

A metal or plastic identification plate shall be permanently 
mounted to the exterior of the building at a minimum of eight (8) 
feet above grade directly in line with the exhaust vent terminal 
for the horizontally vented gas fueled heating appliance or 
equipment. The sign shall read, in print no less the one-half inch 
(½) in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS”. 

1.2.4  Inspection

The state or local gas inspector of the side wall horizontally 
vented gas fueled equipment shall not approve the installation 
unless, upon inspection, the inspector observes carbon monoxide 
detectors and signage installed in accordance with the provisions 
of 248 CMR 5.08 (2) (a) 1 through 4.

1.2.5  Exemptions

The following equipment is exempt from 248 CMR 5.08 (2) (a) 1 
through 4: The equipment listed in Chapter 10 entitled “Equipment 
Not Required To Be Vented” in the most current edition of NFPA 
54 as adopted by the Board; and Product Approved side wall 
horizontally vented gas fueled equipment installed in a room or 
structure separate from the dwelling, building or structure used in 
whole or in part for residential purposes.

1.2.6  Manufacturer Requirements

1.2.6.1  Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally 
vented gas equipment provides a venting system design or 
venting system components with the equipment, the instructions 
provided by the manufacturer for installation of the equipment and 
the venting system shall include:
•  Detailed instructions for the installation of the venting system 

design or the venting system components; and

•  A complete parts list for the venting system design or venting 

system.

1.2.7  Gas Equipment Venting 

System NOT Provided

When the manufacturer of Product Approved side wall horizontally 
vented gas equipment does not provide the parts for venting the 
flue gases, but identifies “special venting systems”, the following 
requirements shall be satisfied by the manufacturer:
•  The referenced “special venting systems” instructions shall 

be included with the appliance or equipment installation 
instructions and;

•  The “special venting systems” shall be Product Approved by 

the Board, and the instructions for that system shall include a 
parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved 
side wall horizontally vented gas fueled equipment, all venting 
instructions, all parts lists for venting instructions, and/or all 
venting design instructions shall remain with the appliance or 
equipment at the completion of the installation.

Содержание NICOLLET-195S NCL-195S

Страница 1: ...RE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage This appliance may be installed in an aftermarket permanently located manufactu...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...s 20 7 4 Restrictor Assembly and Installation 20 7 5 Vertical Terminations 21 7 6 Combination Venting 22 7 7 Exhaust Damper 23 7 8 Secure Vent System 23 7 9 Horizontal Vent Heat Shield Installation 23...

Страница 6: ......

Страница 7: ...he above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the bu...

Страница 8: ...5 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 0 72 kPa Orifice Size DMS 52 60 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer to National...

Страница 9: ...Viewing Area Width Back to Vent Center Inches 31 1 2 18 1 2 5 5 16 14 3 8 1 1 2 16 15 16 11 7 8 7 3 4 Millimeters 825 470 134 365 25 12 431 301 196 Figure 2 1 NCL 195S Unit Dimensions 55 16 134mm 7 19...

Страница 10: ...ed with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with Hussong Mfg s barriers for...

Страница 11: ...a location 3 2 Floor Support and Protection The fireplace must be placed directly on a wood or non combustible surface not linoleum or carpet extending the entire depth and width of the fireplace If t...

Страница 12: ...ance top to ceiling 31 in 787 mm Appliance sides to adjacent sidewall 3 in 76 mm From appliance front 36 in 914 mm Top of appliance to 3 4 in 19mm trim 2 1 4 in 57 mm Mantel 12 in 305 mm deep from app...

Страница 13: ...thickness and fireplace facing materials If using a hearth adjust the rough opening size as necessary to maintain minimum clearance requirements If masonry is to be used optional prepare the necessary...

Страница 14: ...se for every 12 in 305 mm of travel NOTE Elbows listed with approved vent systems for this appliance vary in vertical length Please consult the vent manufacturer s instructions to determine the elbow...

Страница 15: ...FACING AND FINISHING 15 4 0 FACING AND FINISHING 4 1 Mantel Requirements Figure 4 1 Mantel and Trim Requirements 18 457mm 15 381mm 12 305mm 13 343mm 10 267mm 7 191mm 19mm 2 57mm TOP OF FIREPLACE FACE...

Страница 16: ...side the air openings 2 Align the notched tabs located on the back with the slots in the fireplace Raise slightly and push back to desired position 3 Lower the screen front until the notched tabs are...

Страница 17: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Страница 18: ...r 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27...

Страница 19: ...e combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L...

Страница 20: ...n 76 mm 1 in 25 mm 1 in 25 mm 7 2 2 Wall Pass Through Kozy Heat s 800 WPT series or wall thimble products that comply with the required 3 in 76 mm top clearance to combustibles must be installed for a...

Страница 21: ...listed as non combustible per ASTM E 136 Table 7 3 NG LPG Minimum Maximum Vertical Terminations Minimum Vertical Length Maximum Vertical Length 3 ft 914 mm 50 ft 15 2 m VENTING DIAGRAM VERTICAL TERMIN...

Страница 22: ...ble 7 4 NG LPG Minimum Horizontal Vent Terminations Minimum Vertical Rise Minimum Horizontal Run Maximum Horizontal Run 90 elbow 6 in 152 mm 20 ft 6 m Table 7 5 NG LPG Max Vertical Max Horizontal Comb...

Страница 23: ...tabs on top of the fireplace up 2 Install the first vent pipe section 3 Secure vent pipe section to fireplace through tabs with 3 screws Figure 7 3 Secured Vent System ATTACHMENT SCREWS Figure 7 4 Sec...

Страница 24: ...installing any media Follow instructions included with the gas conversion kit CAUTION Disconnect all electric power from the fireplace insert before performing any of these tasks NOTE To avoid damage...

Страница 25: ...o working on any electrical lines NOTE It easier to install the fan kit before connecting the gas line to the control board This appliance when installed must be electrically grounded in accordance wi...

Страница 26: ...side of the burner up to release from burner orifice 8 Remove halogen bulbs 9 Remove and save 7 screws securing control board 10 Lift control board out of firebox being careful not to damage sealing g...

Страница 27: ...t or remove the grounding prong from this plug 9 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes...

Страница 28: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Страница 29: ...osition for remote control operation of the main burner and fireplace features 10 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 30: ...imately 2 seconds move the switch to the ON position The ignition sequence will start again 10 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After appr...

Страница 31: ...lot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD screen wi...

Страница 32: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Страница 33: ...ode Fan s will operate at previous setting There is no delay in start up or stop time 10 8 9 Accent Light Kit The light intensity can be adjusted through 6 levels 1 Press the mode key to index to the...

Страница 34: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 35: ...ri Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 16 mm OPEN 11 2 1 1 Venturi Adjustment NOTE If soot is present on the glass check log positioning before adjusting the venturi...

Страница 36: ...strictor Installation 1 Remove the safety barrier and glass frame assembly 2 Open the exhaust damper by loosening the wing nuts to access the vent exit 3 Bend the tabs on the restrictor included in fi...

Страница 37: ...LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Страница 38: ...s Media Installation on page 24 Improper venturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 11 2 1 Burner Venturi on page 35 Incorre...

Страница 39: ...air intake system is disassembled for any reason reinstall per instructions provided with installation Refer to Section 7 0 Venting on page 20 Performed by Qualified Service Person Frequency Annually...

Страница 40: ...00 652 NG Burner Orifice 52 700 252 IFC Wire Harness Assembly 700 653 LPG Burner Orifice 60 700 260 Pilot Assembly NG 700 551 Conversion Kit NG NCK NCL S Pilot Assembly LPG 700 551 1 Conversion Kit LP...

Страница 41: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 42: ......

Страница 43: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: