Page 23
COMPLETE THE INSTALLATION
1. A) If not previously done, plumb & level the unit and secure the fireplace to the framing using the stud tabs located on the
sides of the unit. The stud-tabs are adjustable to accommodate the thickness of finish material you are using. To
adjust, loosen the screws securing it to the sides of the fireplace and slide to desired position. Re-tighten the screws
to secure in place.
CAUTION: NEVER PERMANENTLY REMOVE THIS ASSEMBLY FROM THE FIREPLACE - IT MUST BE
SECURED IN PLACE REGARDLESS OF FINISH MATERIAL USED.
B) Use screws (not provided) to secure the unit to the flooring through the holes located in the bottom of the outer box.
IMPORTANT - MOBILE HOME INSTALLATIONS: THE FIREPLACE MUST BE SECURED TO THE FLOOR.
C) Complete the fireplace walls, and the fireplace facing.
IMPORTANT: This fireplace has a 10" clearance requirement from the top of the fireplace. If not previously done,
position & secure the top stand-off brackets. Refer to page #12 for complete information.
If tile or marble is used around or over the face of the fireplace, we recommend using rock board as a backer at the top
of the fireplace.
CAUTION:
ONLY NON-COMBUSTIBLE MATERIAL MUST BE USED FOR A MINIMUM OF 10" FROM
THE TOP OF THE FACE AT THE FRONT OF THE FIREPLACE.
COLD AIR TRANSFER:
The surrounding wood chase of the outside wall must be insulated to prevent cold
air from entering the room.
2. Heat Damper Control:
This fireplace has been de-signed certified to be operated
with the damper fully opened or completely closed
depending on the heat output desired without
compromising flame appearance.
To reduce the amount of heat entering the room, pull the
damper control handle (located behind the lower grill) down
and slightly to the right to the fully open position. This
allows more the heat generated from the fireplace to exit
through the vent system rather than into the home.
If more heat is desired, slide the damper control handle to
the left and release to it’s original position.
NOTE: The damper position is located in the upper portion
of the firebox and may be visually checked by looking
through the front viewing glass. Refer to Figure 19.
Damper
Damper
Control
Figure 19
3. THIS STEP SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER OR SERVICE TECHNICIAN:
A) Perform lighting and shutdown procedures as described on pages #25-#26 for Model #55345 and pages #28-#29 for Model
#55345-RF. This should be done prior to replacing the glass so that any necessary adjustments can be made and proper
operation verified.
Содержание MINNETONKA 55345
Страница 38: ...Page 37...
Страница 39: ...Page 38...