1. Run the gas line.   Gas line holes are positioned on both sides of the fireplace for gas line connection. An accessible shut

off valve (included) must be installed up stream from the regulator.

NOTE:  Do not run the incoming gas line in a manner that would obstruct the operation of the optional fan.

2 . This fireplace is designed to accept either a 3/8" or 1/2" gas line approved for gas appliances.  Consult local building codes

to properly size the gas supply line leading to a 3/8" reduction. 

3. Connect the gas line to the manual shut-off valve.

4. Connect the flexible gas line (installed on the millivolt board valve) to the manual shut off valve. 

IMPORTANT:

 ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE MUST BE CHECKED FOR LEAKS!

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system
at test pressures in excess of ½ psi.

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than ½ psi.

Pressure check taps for both the manifold (outgoing) & inlet (incoming) pressures are located in front of the gas valve.  The left pressure tap is the manifold
pressure and the right pressure tap is the incoming pressure.  Follow instructions on page #27 for Model #55345 and page #30 for Model #55345-RF for
checking these pressures.

(H) SECURE THE MILLIVOLT BOARD:

This unit is equipped with the millivolt board , burner, log grate, pilot shield, & cover assembly already installed.  

1. Referring to the ‘INSTALLING THE MILLIVOLT BOARD’ section on pages #32-#33, check to ensure that all (8) screws

securing the millivolt board are in place and properly tightened.    

2. Ensure that the burner tubes are properly positioned over each burner orifice. 

(I)

 

ADJUST

 

COMBUSTION

 

AIR

 

INTAKE

 

SHIELD

 

-

 

VERTICAL

 

TERMINATIONS

 

ONLY:

Flame height & appearance will vary depending upon venting configuration and type of fuel used.   Use the following as a

guideline when adjusting the combustion air intake shield to achieve desired flame appearance.

NOTE: 

Straight vertical runs typically would require the more restriction, while a venting configuration with elbows,

would require less restriction.

The intake shield is marked as shown in Figure 16.  Make 

sure that it is positioned for the type of gas you are using.  

Adjust from that point according to vertical venting.

Vertical terminations  0-10 ft. should be placed at the #1 setting.
Vertical terminations 11-20 ft. should be placed at the #2 setting
Vertical terminations 21-30 ft. should be placed at the #3 setting.

TO ADJUST: Loosen the (2) screws securing the intake

shield,  move to desired position and 

re-tighten the screws.

Figure 16

Содержание MINNETONKA 55345

Страница 1: ...phone Follow your gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation service must be performed by a qualified installer service agency or the gas s...

Страница 2: ...INSTALLATION 14 15 FAN INSTALLATION 16 18 Model 55345 16 17 Model 55345 RF 18 GAS LINE SPECIFICATIONS 19 20 SECURE THE MILLIVOLT BOARD 20 ADJUST COMBUSTION AIR INTAKE SHIELD VERTICAL TERMINATIONS ONLY...

Страница 3: ...PREVENT THE FACING MATERIAL FROM CRACKING AND FALLING OFF DUE TO EXPANSION OF THE FACE WHEN HEATED DO NOT ATTACH FACING MATERIAL DIRECTLY TO THE FACE OF THE UNIT DO NOT OBSTRUCT THE FLOW OF VENTILATIO...

Страница 4: ...age 3 SPECIFICATIONS Height 34 Height to top of stand off 44 1 2 Front width 40 7 8 Back width 29 1 4 Depth 21 3 8 Refer to Diagrams for additional measurements Top Front FIGURE 1 Left side Right side...

Страница 5: ...imum of 10 from unit top Mantel height must be raised 1 for every additional 1 of depth See chart at right for mantel requirements No mantel is allowed from 0 15 from the top of the fireplace HEARTH R...

Страница 6: ...ROVED FOR USE WITH THE SIMPSON DURA VENT DV GS 5 X 8 DIRECT VENT SYSTEM SELKIRK METALBESTOS DIRECT CHIMNEY SYSTEM 5 X 8 DIRECT VENT SYSTEM FOR HORIZONTAL VERTICAL TERMINATIONS THISFIREPLACEISALSOAPPRO...

Страница 7: ...S 45 degree elbow at start followed by a maximum 10 ft CANADA INSTALLATIONS 0 to 2000 ft 45 degree elbow at start followed by a maximum 10 ft 2000 4500 ft Must de rate burner orifices Natural Gas 56 3...

Страница 8: ...ICKNESS FOR THIS PASS THRU IS 4 AND THE MAXIMUM WALL THICKNESS IS 8 Minimum horizontal venting NOTE Horizontal Vent Heat shield must be installed when using a 45 degree elbow to horizontally position...

Страница 9: ...ilated soffit 12 E 6 Outside inside corner 12 F 7 Meter Regulator NOT TO BE INSTALLED ABOVE within 3 ft horizontally from the center line of the regulator 8 Service regulator vent outlet 3 ft radius 9...

Страница 10: ...ney Height Roof Pitch Minimum Chimney Height Flat to 6 12 1 ft 13 12 to 16 12 6 ft 6 12 to 9 12 2 ft 17 12 to 21 12 8 ft 10 12 to 12 12 4 ft CAUTION This gas appliance must not be connected to or join...

Страница 11: ...on the exterior wall for the chimney termination This opening size includes the required 3 clearance on all sides of approved rigidventsystemsandtheKozyHeat 800 series flexible vent system Toachieveth...

Страница 12: ...RMINATIONS 44 1 2 high x 41 3 8 wide x 23 7 8 deep 2 clearance at the back to maintain required vent system clearance and at the sides of the fireplace must be maintained for vertical terminations See...

Страница 13: ...and off brackets to the top of the fireplace using the screws removed in steps 2 3 above Figure 8C Figure 8A Figure 8C HORIZONTAL VENT APPLICATIONS This fireplace is approved for use with the Simpson...

Страница 14: ...THE GLASS ASSEMBLY See Figure 11 A Locate the spring loaded handles securing the glass assembly at the top bottom of the firebox CAUTION TO PREVENT THE GLASS ASSEMBLY FROM FALLING FROM THE FIREPLACE...

Страница 15: ...installation manual Refer to pages 5 9 of this installation manual for complete venting requirements and restrictions Figure 12 HORIZONTAL TERMINATIONS IMPORTANT The Kozy Heat wall pass thru part MTK...

Страница 16: ...gh either interior or exterior walls Install the MTK WPT wall pass thru on both sides of the 14 1 8 square opening and secure with nails or screws NOTE Attachment brackets are included with the termin...

Страница 17: ...speed control assembly and 3 wire nuts are included in the fireplace components packet This optional fan kit TRF 028 includes Right left fan assemblies with thermostatic control switch Components pack...

Страница 18: ...control receptacle assembly into the electrical box with the 2 screws provided 7 Replace the electrical access panel and secure with the 2 screws removed 8 Place the thermostatic control switch on the...

Страница 19: ...ounding plug for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Figure 15 1 Remo...

Страница 20: ...it cavity See the WARNING label affixed to the flexible tubing for additional installation instructions and warnings NATURAL GAS The minimum inlet gas supply pressure 5 0 inches W C 7 0 inches W C rec...

Страница 21: ...nifold pressure and the right pressure tap is the incoming pressure Follow instructions on page 27 for Model 55345 and page 30 for Model 55345 RF for checking these pressures H SECURE THE MILLIVOLT BO...

Страница 22: ...shown in Figure 17A NOTE There are 2 6 logs and no 5 log Figure 17A 1 2 6 3 6 4 3 Brush rockwool burning embers onto the burner and place klinkers onto the burner as shown in Figures 17B 17C Figure 1...

Страница 23: ...wall switch thermostat wire and connect to the top and bottom terminals on the gas valve marked TH REMOTE CONTROL USERS Follow instructions included with the remote control IMPORTANT The insulated cov...

Страница 24: ...MBUSTIBLE MATERIAL MUST BE USED FOR A MINIMUM OF 10 FROM THE TOP OF THE FACE AT THE FRONT OF THE FIREPLACE COLD AIR TRANSFER The surrounding wood chase of the outside wall must be insulated to prevent...

Страница 25: ...of the upper hood into the clips located in the top of the upper air passage NOTE This is a fairly tight fit Figure 20B C Partially thread the 2 screws included in the components packet into the nuts...

Страница 26: ...or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion and loss of warranty 4 Do not use this appliance if any part has...

Страница 27: ...e thermostat or remote control NOTE The pilot will stay lit TO TURN THE PILOT OFF To turn off the pilot push in and turn the control knob to the OFF position DO NOT FORCE WARNING This control valve ha...

Страница 28: ...ition NOTE If manifold pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure check TO C...

Страница 29: ...vice technician to inspect the appliance and to replace any part of the control system which has been under water DONOTSTOREORUSEGASOLINEOROTHERFLAMMABLEVAPORS AND LIQUIDS IN THE VICINITY OF THIS OR A...

Страница 30: ...lace heats TO TURN THE BURNER OFF LOCAL SETTING Turn the control knob clockwise to the pilot position REMOTE SETTING The RT8220A transmitter can shut off the main burner and fan However the control is...

Страница 31: ...gas supply at the manual valve in the gas piping to the appliance or for LP at the tank 9 Loosen but do not remove the inlet tap captive screw 10 Attach a plastic tube with a 1 4 shell ID and connect...

Страница 32: ...SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CAUTION LABELALLWIRESPRIORTO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND D...

Страница 33: ...F Unplug the fan cord from the duplex receptacle then disconnect the 2 wires from the fan cord Note the wires will remain connected to the back of the gas valve Refer to wiring diagram Figure 15 on pa...

Страница 34: ...ht legs of the burner log grate assembly with screws previously removed CAUTION Ensure that the pilot assembly is above the burner log grate assembly and the burner venturies are properly positioned o...

Страница 35: ...piezo Wire on back of piezo button is loose or off Put wire back into place button is depressed Wire from piezo to electrode is loose at electrode Reconnect wire Electrode moved out of position Realig...

Страница 36: ...erator millivolts to operate burner Model 55345 Wall switch remote control Connect properly or disconnect or thermostat not connected properly and use on off switch only or turned to wrong setting See...

Страница 37: ...rner 700 060 Flexible Pilot Tubing Valve to Pilot 700 268 LP Gas orifice 68 front burner 700 083 Piezo Ignitor w wire 700 251 LP Gas orifice 51 back burner 700 092 Millivolt Generator OCK H5168L RF LP...

Страница 38: ...Page 37...

Страница 39: ...Page 38...

Отзывы: