Page 18
MODEL #55345-RF ONLY: FAN INSTRUCTIONS
I
NSTALLATION OF THIS FAN WIRING SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
IMPORTANT: A fan assembly is pre-installed and wired to the RF gas valve in the Model #55345-RF.
The wiring must be done prior to enclosing the sides of the unit. An electrical box & romex connector are pre-installed
on a removable panel on the right side of the fireplace. A duplex receptacle and cover is included in the fireplace
components packet.
NOTE:
Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to your local
electrical codes for specific requirements in your area.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Figure 15
1. Remove the (2) screws securing the removable access panel (with electrical box & romex connector installed) from the right side
of the fireplace.
2. Insert 115V wiring (with ground) through the romex connector and wire to the duplex receptacle. Secure the duplex receptacle to
the electrical box.
3. Place the cover on the electrical box and secure with screw.
4. Replace the electrical access panel and secure with the (2) screws removed.
5. Plug the 3-prong plug on the fan cord into the receptacle.
6. Upon complete installation of this fireplace, follow the lighting & shutdown instructions at the back of this manual as well as the
instructions included in the remote transmitter for complete fan operation guidelines.