Page 18
M. MODEL CSK-31 ONLY: THERMOSTAT - WALL SWITCH - REMOTE INSTALLATION
CAUTION: DO NOT CONNECT HIGH VOLTAGE (115V) WIRE TO THE GAS VALVE!
If desired, a thermostat (wireless style available), wall switch,
or remote control assembly may be used to turn the fireplace
‘OFF’ and ‘ON’. Only ONE of these may be installed. Follow
instructions included with each assembly.
OPTIONAL: Disconnect the ON/OFF rocker switch wires from
the top & bottom terminals on the back side of the gas valve.
Refer to Figure Q-1, page #28 of this manual.
NOTE: INSTALLATION OF A THERMOSTAT OR WALL SWITCH
SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER.
WALL SWITCH / THERMOSTAT USERS:
Run low-voltage (thermostat) wires from the terminals on the
gas valve to the desired location of the wall switch or
thermostat.
Attach the appropriate connector to each wall switch /
thermostat wire and connect to the top and bottom terminals
on the gas valve marked ‘TH’.
REMOTE CONTROL USERS:
Follow instructions included with the remote control.
IMPORTANT: The insulated cover included with the remote
control must be placed over the remote receiver to protect it
from overheating.
Remote Control Wiring Diagram
Figure M-2
Thermostat Wiring Diagram
Figure M-1
IMPORTANT: If the ON/OFF rocker switch wires are not
disconnected, the ON/OFF rocker switch on the millivolt board
must be in the ‘OFF’ position for proper operation of any of
these components.
If the rocker switch is ‘ON’, the fireplace burner will operate
until it is turned ‘OFF’ by the rocker switch. A wall switch,
thermostat, or remote control will not turn the fireplace ‘OFF’
when it has been turned ‘ON’ by the rocker switch.
NOTE: The fireplace must be turned ‘ON’ and ‘OFF’ by the
same method. For example: If the fireplace is turned ‘ON’ by
the remote control, it must be turned ‘OFF’ by the remote
control.
Содержание CSK-31
Страница 33: ...Page 31 ...