Page 22
MODEL #CSK-31-RF ONLY: LIGHTING AND SHUTDOWN PROCEDURES
NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all connections made. If there is
any leakage, bubbles will appear at the point of connection. If bubbles occur, tighten the fittings until the bubbles no longer appear.
IMPORTANT: TEST ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing
of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas valve. Follow instructions on page
#24 for checking these pressures.
FOR YOUR SAFETY - READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A.
This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B.
BEFORE LIGHTING, smell all around the appliance for gas. Be
sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
C.
Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in, or turn by hand, don’t try to
repair it, call a qualified service technician. Forced or attempted
repair may result in a fire or explosion, and loss of warranty.
D.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system which has
been under water.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DUE TO HIGH SURFACE TEMPERATURES, KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY.
This appliance needs fresh air for safe operation and must be installed
so there are provisions for adequate combustion and ventilation air.
WHAT TO DO IF YOU SMELL GAS:
*Do not touch electrical switches.
*Do not try to light any appliance.
*Do not use any phone in your building.
*Follow the gas supplier’s instructions.
*Immediately call your gas supplier from a neighbor’s phone.
*If you cannot reach your gas supplier, call the fire department.
NOTE: Read 1-8 before lighting this insert for the first time. Refer to Figure N-3, page #23.
1.
Set the thermostat to the lowest setting.
2.
Turn off all electric power to the appliance.
3.
Open the doors or lower grill to access the gas valve & controls.
4.
Push in control knob slightly and turn clockwise to the "OFF” position.
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
5.
Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the safety information above.
If you don't smell gas, go to the next step.
6.
Find the pilot - follow metal tube from gas control. The pilot is located inside the combustion chamber.
7.
Push the control knob on the gas valve in slightly and turn counterclockwise to "PILOT".
CSK-31-RF
8.
Push in the control knob all the way and hold in. Push the plunger on the piezo until the pilot is lit.
Pilot
The pilot will generally light with two or three pushes on the igniter. When the pilot is lit, the LED on the control will come on afer
approximately 60 seconds and will blink continuously. Release knob and it will pop back out. Pilot should remain lit. If it goes out,
repeat steps 4 through 8.
Содержание CSK-31