Page 29
Rocker switch not turned “ON”. (Model CMB-31)
Depress switch.
Rocker switch wires not connected. (Model CMB-31)
Check wiring diagram Figure Q-1
to ensure that all wires are secure.
Generator wires loose at regulator terminals
Reposition wire an tighten screws. See
Figures Q-1 & Q-2 for wiring instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinching of wires.
loosening to remove pinched wire.
Generator is not producing enough
Replace generator.
millivolts to operate burner.
Wall switch, remote control or thermostat not
Connect properly or disconnect
connected properly or turned to wrong setting. See
and use ON/OFF switch only.
Figures M-1 & M-2, page #18. (Model CMB-36)
5.
Burner won't stay lit
Generator wires loose on
Reposition wires and tighten screws
valve terminals.
See Figures Q-1 & Q-2 for wiring
instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinched wires.
loosening to remove pinched wire.
Generator is not producing enough
Check millivolt reading, replace
millivolts to sustain burner operation.
generator if necessary.
Refractory panels not positioned
Secure refractory panels with
against firebox.
high-temp sealant.
WIRING DIAGRAM
Model CMB-31-RF
Figure Q-2
REPLACEMENT PARTS
Replacement parts are available through your local dealer. Information on optional components not listed
below, is also available through your dealer.