3. CONNECT THE VENT SYSTEM TO THE AIR DUCT
A. Place the air duct into the existing fireplace opening. Figure E-4
B. Place a bead of sealant (provided) around the 3” exhaust pipe (with label) and slide it inside the 3" collar
marked ‘Exhaust’ on the duct. Secure with (3) ½" self-tapping screws, provided. Apply additional
sealant around the joint to ensure an air tight seal. Figure E-5.
C. Apply a liberal bead of sealant (provided) around the 3” collar on the air duct. Slide the 3” combustion
intake pipe over the collar and secure with (3) ½" self-tapping screws, provided. To ensure an air-tight
seal, apply additional sealant around the joint. Figure E-5
.
Figure E-4
Figure E-5
F. POSITION THE FIREPLACE INSERT:
1. #CMB-FLP Floor Protector Installation:
ZERO-CLEARANCE INSTALLATIONS: If you have removed the floor in the existing zero-clearance
fireplace, the #CMB-FLP floor protector must be installed over the exposed surface to protect to
combustible materials.
To install the #CMB-FLP floor protector:
A. Set the floor protector, insulation side down,
in desired position over the exposed
combustible material flooring.
Place the insert in the fireplace opening on
top of the #CMB-FLP floor protector.
IMPORTANT:
The #CMB-FLP and bottom of the fireplace insert
are the same size & shape. Make sure that the
insert is properly aligned onto the #CMB-FLP
floor protector.
Figure F-1
#CMB-FLP
Floor Protector
2. Slide the insert into the fireplace opening.