Page 9
TERMINATION CAP
INTAKE COLLAR
NOTE: Collar extends through the
bottom plate
Exhaust Collar
NOTE: Collar extends through the
middle divider plate
IMPORTANT:
INSTALL TERMINATION CAP WITH EXHAUST COLLAR
ON THE RIGHT SIDE. THE EXHAUST COLLAR ON
THE AIR DUCT FOR THE FIREPLACE IS ON THE RIGHT .
KOZY HEAT #816-CL CO-LINEAR VENT SYSTEM:
The co-linear pipe included in this vent system is designed to extend up to 30 ft.
IMPORTANT:
The 3" exhaust pipe and exhaust collar on the termination cap can be identified by the label
attached to each end of the pipe and the label on the collar. It is imperative for proper operation
of this insert that the exhaust and combustion air pipes be connected to the correct collar on the
termination kit and air duct for the insert.
A. Carefully extend the 3” exhaust and combustion intake pipes to equal the total chimney
length required.
B.
1. Slide the 3" intake pipe (end without the collar) onto the collar on the termination cap and
secure with 3 self-tapping screws (provided).
2. Place a bead of sealant around the inner edge of the end of the 3" exhaust pipe (with
label) without the collar and slide onto the corresponding collar on the termination cap
(collar with label). Secure with 3 self-tapping screws (provided). Apply additional
sealant around the joint to ensure a seal.
FIGURE E-1
OTHER APPROVED 3" X 3" CO-LINEAR VENT SYSTEMS:
Dura-Vent, Ameri-Vent Direct, & Selkirk Metalbestos - Follow instructions included from the vent pipe
manufacturer as well as the venting installation requirements as outlined in this installation manual.
2. RUN THE VENT SYSTEM THROUGH THE EXISTING CHIMNEY
ˆ
OPTIONAL: We recommend wrapping the first 3 ft. of the vent system below the termination cap with non-faced
fiberglass insulation (secure with wire) before running it through the existing chimney. This will prevent cold air
from coming down the existing chimney.
NOTE: If there are offsets in the existing chimney, it may be easier to place a weighted rope around the end of the
each 3" pipe to guide them through it.