Page 14
1. Secure the electrical access panel to the side of the fireplace.
2. Place the thermostatic control switch on the bottom of the fireplace.
3. Plug the cord into the receptacle in the electrical box.
4. Turn the speed control counter-clockwise until it ‘clicks’. This is the ‘OFF’ position.
5. Turn the speed control ‘ON’ by turning the knob clockwise past the ‘click’ - this is the highest
setting.
Figure I-1
NOTE: The fan will not operate unless the speed control has been turned ‘ON’. The fan will not turn ‘ON’ until sufficient heat is
applied to the thermostatic control switch . The fan will turn ‘ON’ and ‘OFF’ automatically when the fireplace heats and cools.
Adjust fan to desired speed while it is running.
TEMPERATURE CONTROL SWITCH POSITION: Prior to adjusting the temperature control switch, unplug the 3-prong plug on the
fan cord from the receptacle. Adjust the position of the temperature control switch to a warmer location under the firebox to
turn the fan ‘ON’ sooner or move it to a cooler location under the firebox to turn the fan ‘ON’ later. The fan will turn on when the
sensor in the temperature control switch reaches 110
o
F and will turn ‘OFF’ when the sensors reach 90
o
F. After adjustment, plug
the 3-prong plug on the fan cord into the receptacle.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70-Current edition. or the Canadian Electrical Code, CSA C22.1.
Model #CMB-31-RF only: Refer also to Figure C-2 page #8.
1. Secure the electrical access panel to the side of the fireplace.
2. Plug the cord into the receptacle in the electrical box.
3. Upon complete installation of this fireplace, follow the lighting & shutdown instructions at the back
of this manual as well as the instructions included in the remote transmitter for complete fan
operation guidelines.
J) ATTACH THE SHROUD
Shroud assembly includes:
(1) Shroud top
(2) 10-24 x 1" RH Philips Mch Screw (#300388)
(1) Shroud left side
(6) 8 x 3/8" Phillips PH-Type B Blk Zinc SMS (#300121)
(1) Shroud right side
(4) 10-24 x 1/2" PH Phillips Truss head Screw BZ (300338-1)
Speed Control /
receptacle assembly
Thermostatic
Control Switch