PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting the fireplace and venting.
This fireplace insert is to be installed into a solid fuel masonry or factory built non-combustible fireplace that has been installed in
accordance with the National, Provincial, State and local building codes.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
SPECIFICATIONS
ADDITIONAL COMPONENTS REQUIRED
Vent System;
Part #815-CL
: For use with minimum 6” x 8” I.D. masonry or 8” I.D. Class A metal chimneys
- Includes 12 ft. (3.66 m)
compressed, expandable to 25 ft (7.62 m) co-
linear 3” x 4” flexible chimney, and termination cap.
Part #510: Used in conjunction with #815-CL to extend termination up to a maximum of 30 ft. (9.14 m).
Other approved venting
: Selkirk, ICC, American Metals, Security
Shrouds - 3 pc & 4 pc.:
Standard shrouds are available for this insert and will fit most applications. Custom shrouds may be ordered on a
non-returnable basis. When ordering a custom shroud, please specify existing fireplace front opening height and
width. Grill set or clean face frame (required) in various finishes purchased separately.
Or
Blank Shrouds - 3 & 4 pc.:
Blank shrouds are available for on-site custom fit applications and are sized to the opening after the insert has
been installed. The interior perimeter is properly sized to fit onto the insert. The outer perimeter must be cut,
formed and finished (painted). Grill set or clean face frame (required) in various finishes purchased separately.
Or
Full Door Shrouds:
Full door decorative shrouds are available for this insert and are used in place of a standard or blank shroud.
THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES.
EXISTING FIREPLACE SPECIFICATIONS
EXISTING FIREPLACE REQUIREMENTS
DETERMINE LENGTH OF EXISTING CHIMNEY
1.
Remove and discard existing chimney cap.
2. Position one person at fireplace and another person at top of chimney.
Measure from fireplace base to top of chimney.
Subtract 24” (610mm) (height of insert).
This is the total length of co-linear flexible aluminum you will require.
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:_________________
LESS 24" (610mm) (HEIGHT OF INSERT): -24" (610mm)____
TOTAL CHIMNEY LENGTH REQUIRED:
_________________
CAUTION
This appliance must not be connected to or joined with any other chimney flue
serving another appliance.
NOTE
It is helpful to have two people complete next step to determine chimney height.
The existing fireplace & chimney must be clean and in good working order and constructed of non-combustible materials.
A gas line must be able to be installed to insert.
Provisions made to provide electrical power to operate insert fan and thermostatic control (if used).
Any chimney clean-outs must fit properly.
Existing Chimney must be comprised of one of the following: Factory built chimney: 8” (203mm) minimum inside diameter.
Masonry Chimney: 6" x 8" minimum inside diameter.
Existing Chimney Height:
Minimum: 11 ft. (3.35 m)
Maximum: 40 ft. (12.19 m)