background image

AUSTRALIAN 

RECOMMENDED MEZZO 

INSTALLATION 

INSTRUCTION

FOR MODELS:

MEZZO-1000-AU
MEZZO-1300-AU

MEZZO-1300ST-AU

MEZZO-1600-AU

23/03/2017

Ver.1

Summary of Contents for MEZZO-1000-AU

Page 1: ...AUSTRALIAN RECOMMENDED MEZZO INSTALLATION INSTRUCTION FOR MODELS MEZZO 1000 AU MEZZO 1300 AU MEZZO 1300ST AU MEZZO 1600 AU 23 03 2017 Ver 1 ...

Page 2: ... to timber frame only At no point is the wall lining to be screwed or glued to the unit The unit must be able to expand and contract independently to the frame and wall lining otherwise cracking will occur Unit and heat board is to finish flush with front of timber frame so that 9mm wall lining can be correctly finished If the fibre cement sheeting is to be fixed to the heat board Selleys 401 sili...

Page 3: ...S Variant Vent opening A Opening height B Opening depth C Opening width D MEZZO 1000 AU 254 1085 477 1275 MEZZO 1300 AU 254 1085 477 1580 MEZZO 1600 AU 254 1237 478 1885 MEZZO AUSTRALIAN FRAMING DIMENSIONS 23 03 2017 Ver 1 3 ...

Page 4: ...MEZZO SEE THROUGH AUSTRALIAN FRAMING DIMENSIONS MEZZO SEE THROUGH FRAMING DIMENSIONS Variant Vent opening Opening height Opening depth Opening width MEZZO 1300ST AU 254 1085 464 1580 23 03 2017 Ver 1 4 ...

Page 5: ...TAIL 9mm fibre cement sheeting under the unit 9mm fibre cement sheeting Opening Opening 23 03 2017 Ver 1 5 A Timber frame installed flush with the heat board material on the unit typical both sides 9mm fibre cement sheeting heat board material DETAIL A ...

Page 6: ...ed flush with the heat board material on the unit this side only 9mm fibre cement sheeting 9mm fibre cement sheeting under the unit Opening 25mm air gap from rear of unit to timber framing with fibre cement sheeting 23 03 2017 Ver 1 6 heat board material A DETAIL A ...